Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 24 von 158
Regional anesthesia and pain medicine, 2020-07, Vol.45 (7), p.552
2020

Details

Autor(en) / Beteiligte
Titel
Cervical erector spinae plane block: a cadaver study
Ist Teil von
  • Regional anesthesia and pain medicine, 2020-07, Vol.45 (7), p.552
Ort / Verlag
England
Erscheinungsjahr
2020
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • Cervical erector spinae plane (ESP) block has been described to anesthetize the brachial plexus (BP), however, the mechanism of its clinical effect remains unknown. As the prevertebral fascia encloses the phrenic nerves, BP and erector spinae muscles to form a prevertebral compartment, a local anesthetic injected in the cervical ESP could potentially spread throughout the prevertebral compartment. This study utilizes cadaveric models to evaluate the spread of ESP injections at the C6 and C7 levels to determine whether the injection can reach the BP and its surrounding structures. For each of the five cadavers, an ESP injection posterior to the transverse process of C6 was performed on one side, and an ESP injection posterior to the transverse process of C7 was performed on the contralateral side. Injections were performed under ultrasound guidance and consisted of a 20 mL mixture of 18 mL water and 2 mL India ink. After cadaver dissection, craniocaudal and medial-lateral extent of the dye spread in relation to musculoskeletal anatomy as well as direct staining relevant nerves was recorded. The degree of dye staining was categorized as "deep," "faint," or "no." The phrenic nerve was deeply stained in 1 injection and faintly stained in 2 injections. Caudally, variable staining of C8 (100%) and T1 (50%) roots were seen. Faintly staining at C4 root was only seen in one sample (10%). There was variable staining of the anterior scalene muscles (40%) anterior to the BP and the rhomboid intercostal plane caudally (30%). Ultrasound-guided cervical (C6 and C7) ESP injections consistently stain the roots of the BP and dorsal rami. This study supports the notion that the cervical ESP block has the potential to provide analgesia for patients undergoing shoulder and cervical spine surgeries.
Sprache
Englisch
Identifikatoren
eISSN: 1532-8651
DOI: 10.1136/rapm-2019-101154
Titel-ID: cdi_pubmed_primary_32321860

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX