Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 16 von 4615

Details

Autor(en) / Beteiligte
Titel
A 3-year Randomized Clinical Trial of MiSight Lenses for Myopia Control
Ist Teil von
  • Optometry and vision science, 2019-08, Vol.96 (8), p.556
Ort / Verlag
United States
Erscheinungsjahr
2019
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • Results of this randomized, double-masked clinical trial demonstrate the effectiveness of the MiSight soft contact lens in slowing myopia progression over multiple years. The purpose of this study was to quantify the effectiveness of MiSight daily disposable soft contact lens in slowing the progression of juvenile-onset myopia. Myopic children (spherical equivalent refraction, -0.75 to -4.00 D; astigmatism, <1.00 D) aged 8 to 12 years with no prior contact lens experience were enrolled in a 3-year, double-masked, randomized clinical trial at four investigational sites in four countries. Subjects in each group were matched for age, sex, and ethnicity and were randomized to either a MiSight 1-day contact lens (test) or Proclear 1-day (control; omafilcon A) and worn on a daily disposable basis. Primary outcome measures were the change in cycloplegic spherical equivalent refraction and axial length. Of the subjects enrolled, 75.5% (109/144) completed the clinical trial (53 test, 56 control). Unadjusted change in spherical equivalent refraction was -0.73 D (59%) less in the test group than in the control group (-0.51 ± 0.64 vs. -1.24 ± 0.61 D, P < .001). Mean change in axial length was 0.32 mm (52%) less in the test group than in the control group (0.30 ± 0.27 vs. 0.62 ± 0.30 mm, P < .001). Changes in spherical equivalent refraction and axial length were highly correlated (r = -0.90, P < .001). Over the course of the study, there were no cases of serious ocular adverse events reported. Four asymptomatic corneal infiltrative (one test, three control) events were observed at scheduled study visits. Results of this clinical trial demonstrate the effectiveness of the MiSight daily disposable soft contact lens in slowing change in spherical equivalent refraction and axial length.
Sprache
Englisch
Identifikatoren
eISSN: 1538-9235
DOI: 10.1097/OPX.0000000000001410
Titel-ID: cdi_pubmed_primary_31343513

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX