Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...

Details

Autor(en) / Beteiligte
Titel
Intra-Cochlear Electrocochleography During Cochear Implant Electrode Insertion Is Predictive of Final Scalar Location
Ist Teil von
  • Otology & neurotology, 2018-09, Vol.39 (8), p.e654-e659
Ort / Verlag
United States
Erscheinungsjahr
2018
Quelle
MEDLINE
Beschreibungen/Notizen
  • Electrocochleography (ECochG) patterns observed during cochlear implant (CI) electrode insertion may provide information about scalar location of the electrode array. Conventional CI surgery is performed without actively monitoring auditory function and potential damage to intracochlear structures. The central hypothesis of this study was that ECochG obtained directly through the CI may be used to estimate intracochlear electrode position and, ultimately, residual hearing preservation. Intracochlear ECochG was performed on 32 patients across 3 different implant centers. During electrode insertion, a 50-ms tone burst stimulus (500 Hz) was delivered at 110 dB SPL. The ECochG response was monitored from the apical-most electrode. The amplitude and phase changes of the first harmonic were imported into an algorithm in an attempt to predict the intracochlear electrode location (scala tympani [ST], translocation from ST to scala vestibuli [SV], or interaction with basilar membrane). Anatomic electrode position was verified using postoperative computed tomography (CT) with image processing. CT analysis confirmed 25 electrodes with ST position and 7 electrode arrays translocating from ST into SV. The ECochG algorithm correctly estimated electrode position in 26 (82%) of 32 subjects while 6 (18%) electrodes were wrongly identified as translocated (sensitivity = 100%, specificity = 77%, positive predictive value = 54%, and a negative predictive value = 100%). Greater hearing loss was observed postoperatively in participants with translocated electrode arrays (36 ± 15 dB) when compared with isolated ST insertions (28 ± 20 dB HL). This result, however, was not significant (p = 0.789). Intracochlear ECochG may provide information about CI electrode location and hearing preservation.
Sprache
Englisch
Identifikatoren
ISSN: 1531-7129
eISSN: 1537-4505
DOI: 10.1097/MAO.0000000000001906
Titel-ID: cdi_pubmed_primary_30113557

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX