Am Donnerstag, den 15.8. kann es zwischen 16 und 18 Uhr aufgrund von Wartungsarbeiten des ZIM zu Einschränkungen bei der Katalognutzung kommen.
Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 25 von 97

Details

Autor(en) / Beteiligte
Titel
Interior tomography in microscopic CT with image reconstruction constrained by full field of view scan at low spatial resolution
Ist Teil von
  • Physics in medicine & biology, 2018-03, Vol.63 (7), p.075006-075006
Ort / Verlag
England: IOP Publishing
Erscheinungsjahr
2018
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • In high resolution (microscopic) CT applications, the scan field of view should cover the entire specimen or sample to allow complete data acquisition and image reconstruction. However, truncation may occur in projection data and results in artifacts in reconstructed images. In this study, we propose a low resolution image constrained reconstruction algorithm (LRICR) for interior tomography in microscopic CT at high resolution. In general, the multi-resolution acquisition based methods can be employed to solve the data truncation problem if the project data acquired at low resolution are utilized to fill up the truncated projection data acquired at high resolution. However, most existing methods place quite strict restrictions on the data acquisition geometry, which greatly limits their utility in practice. In the proposed LRICR algorithm, full and partial data acquisition (scan) at low and high resolutions, respectively, are carried out. Using the image reconstructed from sparse projection data acquired at low resolution as the prior, a microscopic image at high resolution is reconstructed from the truncated projection data acquired at high resolution. Two synthesized digital phantoms, a raw bamboo culm and a specimen of mouse femur, were utilized to evaluate and verify performance of the proposed LRICR algorithm. Compared with the conventional TV minimization based algorithm and the multi-resolution scout-reconstruction algorithm, the proposed LRICR algorithm shows significant improvement in reduction of the artifacts caused by data truncation, providing a practical solution for high quality and reliable interior tomography in microscopic CT applications. The proposed LRICR algorithm outperforms the multi-resolution scout-reconstruction method and the TV minimization based reconstruction for interior tomography in microscopic CT.
Sprache
Englisch
Identifikatoren
ISSN: 0031-9155, 1361-6560
eISSN: 1361-6560
DOI: 10.1088/1361-6560/aab46f
Titel-ID: cdi_pubmed_primary_29509149

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX