Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 3 von 17

Details

Autor(en) / Beteiligte
Titel
A comparative effectiveness trial of two faecal immunochemical tests for haemoglobin (FIT). Assessment of test performance and adherence in a single round of a population-based screening programme for colorectal cancer
Ist Teil von
  • Gut, 2018-03, Vol.67 (3), p.485
Ort / Verlag
England
Erscheinungsjahr
2018
Quelle
MEDLINE
Beschreibungen/Notizen
  • To compare acceptability and diagnostic accuracy of a recently available faecal immunochemical test (FIT) system (HM-JACKarc) with the FIT routinely used in an established screening programme (OC-Sensor). Randomised controlled trial (ISRCTN20086618) within a population-based colorectal cancer (CRC) screening programme. Subjects eligible for invitation in the Umbria Region (Italy) programme were randomised (ratio 1:1) to be screened using one of the FIT systems. Screening uptake among the 48 888 invitees was the same for both systems among subjects invited in the first round and higher with OC-Sensor than with HM-JACKarc (relative risk (RR): 1.03; 95% CI 1.02 to 1.04) among those invited in subsequent rounds. Positivity rate (PR) was similar with OC-Sensor (6.5%) as with HM-JACKarc (6.2%) among subjects performing their first FIT screening and higher with OC-Sensor (5.6%, RR: 1.25, 95% CI 1.12 to 1.40) than with HM-JACKarc (4.4%) among those screened in previous rounds. Positive predictive value (PPV) (OC-Sensor: 25.9%, HM-JACKarc: 25.6%) and detection rate (DR) (OC-Sensor: 1.40%; HM-JACKarc: 1.42%) for advanced neoplasia (AN: CRC + advanced adenoma) were similar among subjects performing their first FIT screening. The differences in the AN PPV (OC-Sensor: 20.3%, HM-JACKarc: 22.6%) and DR (OC-Sensor: 0.96%, HM-JACKarc: 0.83%) among those screened in previous rounds were not statistically significant. The number needed to scope to detect one AN was 3.9 (95% CI 5.8 to 2.9) and 3.9 (95% CI 5.5 to 2.9) at first and 4.9 (95% CI 5.8 to 4.2) and 4.4 (95% CI 5.3 to 3.7) at subsequent screening, with OC-Sensor and HM-JACKarc, respectively. Our results suggest that acceptability and diagnostic performance of HM-JACKarc and of OC-Sensor systems are similar in a screening setting. ISRCTN20086618; Results.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX