To explore the change of the amplitude of P wave, T wave and ST segment of 12 lead electrocardiogram (ECG) in children with breath holding spell.
A total of 29 children (24 males and 5 females) with breath holding spell in Second Xiangya Hospital, Central South University were enrolled for this study from October, 2009 to September, 2015. Their ages ranged from 3 months to 6 years, with an average of 1.82±1.27 years old. The control group consisted of 30 age-matched and gender-matched healthy children. All subjects were underwent electrocardiography by the SR-1000A comprehensive automatic electrocardiograph analyzer, and the changes of the ECG parameters were compared between the two groups.
Compared with the control group, the amplitude of P-wave of V5 lead was decreased [(44.10±23.98) vs (58.30±21.19) μV, P<0.05], the amplitude of T-wave of V6 lead was increased [(423.80±122.6) vs (350.00±105.73) μV, P<0.05], the amplitude of ST segment of II lead was increased [(84.80±39.97) vs (57.30±38.77) μV, P<0.05],