Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 5 von 256

Details

Autor(en) / Beteiligte
Titel
Endoleak detection after endovascular repair of thoracic aortic aneurysm using dual-source dual-energy CT: suitable scanning protocols and potential radiation dose reduction
Ist Teil von
  • American journal of roentgenology (1976), 2013-02, Vol.200 (2), p.451
Ort / Verlag
United States
Erscheinungsjahr
2013
Quelle
MEDLINE
Beschreibungen/Notizen
  • The objective of our study was to evaluate the diagnostic performance of dual-source dual-energy CT (DECT) in the detection of endoleaks after thoracic endovascular aortic repair for thoracic aortic aneurysm and to investigate if a double-phase (arterial and dual-energy late delayed phase) or a single-phase (dual-energy late delayed phase) acquisition can replace the standard triphasic protocol. All DECT examinations performed for evaluation after thoracic endovascular aortic repair during a 30-month period were retrospectively reviewed. An initial single-source unenhanced acquisition was followed by a single-source arterial phase acquisition and a dual-energy 300-second late delayed phase acquisition. "Virtual noncontrast images" were generated from the dual-energy acquisition. Two independent and blinded radiologists evaluated the cases during three reading sessions: session A (triphasic protocol: standard unenhanced, arterial phase, and late delayed phase), session B (virtual noncontrast and late delayed phase), and session C (virtual noncontrast, arterial phase, and late delayed phase). The diagnostic accuracies of sessions B and C were calculated using session A as the reference standard. Contrast-to-noise ratios and effective radiation doses were calculated. Forty-eight patients (mean age, 66 years; age range, 19-84 years) underwent 74 triple-phase CT examinations. The single-phase studies (session B) were characterized by 85.7% sensitivity, 100% specificity, 100% negative predictive value (NPV), and 94.6% positive predictive value (PPV). The dual-phase study (session C) revealed 100% sensitivity, 100% specificity, 100% NPV, and 100% PPV. The use of the dual-phase protocol and single-phase protocol resulted in a radiation exposure reduction of 19.5% and 64.1%, respectively. Virtual noncontrast and late delayed phase images reconstructed from a single DECT acquisition can replace the standard triphasic protocol in follow-up examinations after thoracic endovascular aortic repair, thereby providing a significant dose reduction.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX