Titel
Endoscopic management of malignant biliary obstruction by means of covered metallic stents: primary stent placement vs. re-intervention
Ist Teil von
  • Endoscopy, 2011-12, Vol.43 (12), p.1039-1044
Ort / Verlag
Germany
Erscheinungsjahr
2011
Quelle
MEDLINE
Beschreibungen/Notizen
  • Recent progress in chemotherapy has prolonged the survival of patients with malignant biliary strictures, leading to increased rates of stent occlusion. Occlusion of covered metallic stents now occurs in about half of all patients with malignant biliary strictures. The removal of metallic stents followed by placement of a second stent has been attempted, but outcomes remain controversial. The aim of the current study was to evaluate the effectiveness and safety of the primary placement and secondary placement (re-intervention) of covered metallic stents and to assess the feasibility and safety of stent removal. The study included 186 patients with unresectable malignant biliary strictures who underwent primary stent placement between October 2001 and March 2010.  Covered biliary self-expandable metal stents (SEMSs) were removed in 39 of these patients, and 36 underwent re-intervention. The patency times, occlusion rates of the first stent and re-intervention, success rates of stent removal, and complications were investigated. Covered SEMSs were placed in 186 patients. The median patency time of the first stent was 352 days. Stent occlusion occurred in 48.9 % of the patients and was mainly caused by debris or food residue (37 %), dislocation (19 %), and migration with hyperplasia (19 %). Stent removal was attempted in 50 patients and was successful without complication in 39 (78 %). Most of the patients in whom stent removal was unsuccessful had migration with hyperplasia. The median patency time of the second stent was 263 days. The stent patency time did not significantly differ between the first and the second stent. Covered SEMSs could be safely removed at the time of stent occlusion. Patency rates were similar for initial stent placement and re-intervention.
Sprache
Englisch
Identifikatoren
ISSN: 0013-726X
eISSN: 1438-8812
DOI: 10.1055/s-0030-1256769
Titel-ID: cdi_pubmed_primary_21971926

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX