Risk of bioaerosol contamination with Aspergillus species before and after cleaning in rooms filtered with high-efficiency particulate air filters that house patients with hematologic malignancy
Ist Teil von
  • Infection control and hospital epidemiology, 2007-09, Vol.28 (9), p.1066-1070
Ort / Verlag
United States
Erscheinungsjahr
2007
Quelle
MEDLINE
Beschreibungen/Notizen
  • To examine the impact of cleaning and directional airflow on environmental contamination with Aspergillus species in hospital rooms filtered with high-efficiency particulate air (HEPA) filters that house patients with hematologic malignancy. Detailed environmental assessment. A 475-bed tertiary cancer center in the southern United States. From April to October 2004, 1,258 surface samples and 627 bioaerosol samples were obtained from 74 HEPA-filtered rooms (in addition, 88 outdoor bioaerosol samples were obtained). Samples were collected from rooms cleaned within 1 hour after patient discharge and from rooms before cleaning. Positive and negative airflows were evaluated using air-current tubes at entrances to patient rooms. Of 1,258 surface samples, 3.3% were positive for Aspergillus species. Univariate analysis showed no relationship between cleaning status and occurrence of Aspergillus species. Of 627 bioaerosol samples, 7.3% were positive for Aspergillus species. Multiple logistic analysis revealed independently significant associations with detection of Aspergillus species. Cleaned rooms positive for Aspergillus species had a higher geometric mean density of colonies than that of rooms sampled before cleaning (18.9 vs 5.5 colony-forming units [cfu] per cubic meter; P=.0047). Rooms with positive airflow had a detection rate for bioaerosol samples equivalent to that of rooms with negative airflow (7.3% vs 7.8%; P=.8). There was no significant difference in the density of Aspergillus species between rooms with negative airflow and rooms with positive airflow (12.5 vs 8.4 cfu/m(3); P=.33). Concentration of bioaerosol contamination with Aspergillus species was increased in rooms sampled 1 hour after cleaning compared with rooms sampled before cleaning, suggesting a possible correlation between re-entrained bioaerosols (ie, those suspended by activity in the room) after cleaning and the risk of nosocomial invasive aspergillosis.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX