Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 25 von 43

Details

Autor(en) / Beteiligte
Titel
Diagnostic accuracy of digital mammography in patients with dense breasts who underwent problem-solving mammography: effects of image processing and lesion type
Ist Teil von
  • Radiology, 2003-01, Vol.226 (1), p.153
Ort / Verlag
United States
Erscheinungsjahr
2003
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • To determine effects of lesion type (calcification vs mass) and image processing on radiologist's performance for area under the receiver operating characteristic curve (AUC), sensitivity, and specificity for detection of masses and calcifications with digital mammography in women with mammographically dense breasts. This study included 201 women who underwent digital mammography at seven U.S. and Canadian medical centers. Three image-processing algorithms were applied to the digital images, which were acquired with Fischer, General Electric, and Lorad digital mammography units. Eighteen readers participated in the reader study (six readers per algorithm). Baseline values for reader performance with screen-film mammograms were obtained through the additional interpretation of 179 screen-film mammograms. A repeated-measures analysis of covariance allowing unequal slopes was used in each of the nine analyses (AUC, sensitivity, and specificity for each of three machines). Bonferroni correction was used. Although lesion type did not affect the AUC or sensitivity for Fischer digital images, it did affect specificity (P =.0004). For the General Electric digital images, AUC, sensitivity, and specificity were not affected by lesion type. For Lorad digital images, the results strongly suggested that lesion type affected AUC and sensitivity (P <.0001). None of the three image-processing methods tested affected the AUC, sensitivity, or specificity for the Fischer, General Electric, or Lorad digital images. Findings in this study indicate that radiologist's interpretation accuracy in interpreting digital mammograms depends on lesion type. Interpretation accuracy was not influenced by the image-processing method.
Sprache
Englisch
Identifikatoren
ISSN: 0033-8419
eISSN: 1527-1315
DOI: 10.1148/radiol.2261012024
Titel-ID: cdi_pubmed_primary_12511684

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX