Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Distribution accuracy of a decentralized unit dose system
Ist Teil von
American journal of health-system pharmacy, 1975-11, Vol.32 (11), p.1124-1126
Ort / Verlag
United States
Erscheinungsjahr
1975
Quelle
MEDLINE
Beschreibungen/Notizen
Unit dose medication carts in a 500-bed university hospital were monitored for accuracy and completeness after delivery to the nursing station. The contents of the cart were compared with the nurse's patient medication record. Discrepancies were recorded for evaluation. All medication cart distribution errors found were analyzed to identify the source and were tabulated to determine error rate. Three major categories of errors were discovered: pharmacy technician errors not corrected by the pharmacist, errors associated with nurse's patient medication records, and errors resulting from lost orders.