Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Harmonic analysis of some light sources used for domestic lighting
Ist Teil von
Lighting research & technology (London, England : 2001), 2011-09, Vol.43 (3), p.371-380
Ort / Verlag
London, England: SAGE Publications
Erscheinungsjahr
2011
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
Measurements of voltage and current waveforms produced by a variety of light sources used for domestic lighting are presented. Incandescent, halogen, compact fluorescent, linear tubular fluorescent (with a magnetic choke and with an electronic ballast) and two forms of light emitting diode (LED) lamps were measured. From the voltage and current waveforms measured, the total harmonic distortion (THD), distortion and displacement power factors (PFs) and the net PF are estimated for the different lamp types. This analysis suggests that compact fluorescent and LED lamps may exhibit high levels of THD due to their spiky current waveforms.