Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 17 von 1388
Photomedicine and laser surgery, 2011-12, Vol.29 (12), p.785-787
2011
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
How to Report Low-Level Laser Therapy (LLLT)/Photomedicine Dose and Beam Parameters in Clinical and Laboratory Studies
Ist Teil von
  • Photomedicine and laser surgery, 2011-12, Vol.29 (12), p.785-787
Ort / Verlag
United States: Mary Ann Liebert, Inc
Erscheinungsjahr
2011
Quelle
MEDLINE
Beschreibungen/Notizen
  • Background: Dose and beam parameters are critical for successful laser, LED, and other light therapy treatments; however, in our experience, researchers frequently make critical errors and omissions when submitting papers for publication. Journals frequently publish studies with missing data, mathematical errors, and no reported verification of beam parameters. This makes reproducibility impossible, and further confounds an already complex subject. Objective: This article is intended to be a reference document for non-physicist researchers conducting low-level laser therapy (LLLT) laboratory studies and clinical trials to help them design and report the beam and dose aspects of their trials. Recommendations: It provides a checklist to help LLLT researchers understand and report all the necessary parameters for a repeatable scientific study. It includes the eight most important beam parameters to report, which are: wavelength, power, irradiation time, beam area at the skin or culture surface (this is not necessarily the same as the aperture size), pulse parameters, anatomical location, number of treatments, and interval between treatments. The three commonly used dose parameters are time, energy, and energy density. In addition, more thorough reporting would include coherence, application technique (contact, projection, scanning, pressure), beam profile, and spectral width, as these may also be considered important. Beam power often decreases as the device warms up and as the device ages; therefore, this should be checked routinely during an experiment/trial. Measurements of beam area and beam power require special instruments and trained technicians to operate them. Power measurements should be taken before, after, and at frequent intervals during research trials. Conclusion: Reviewers should insist that the minimum eight most important beam parameters are included, and authors should take care to measure and record these accurately before, during, and after an experiment or clinical trial.
Sprache
Englisch
Identifikatoren
ISSN: 1549-5418
eISSN: 1557-8550
DOI: 10.1089/pho.2011.9895
Titel-ID: cdi_proquest_miscellaneous_911941394

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX