Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 25 von 22348

Details

Autor(en) / Beteiligte
Titel
Rapid Exclusion of Acute Myocardial Infarction in Patients With Undetectable Troponin Using a High-Sensitivity Assay
Ist Teil von
  • Journal of the American College of Cardiology, 2011-09, Vol.58 (13), p.1332-1339
Ort / Verlag
New York, NY: Elsevier Inc
Erscheinungsjahr
2011
Quelle
EZB-FREE-00999 freely available EZB journals
Beschreibungen/Notizen
  • Objectives This paper sought to evaluate whether high sensitivity troponin (hs-cTnT) can immediately exclude acute myocardial infarction (AMI) at a novel ‘rule out' cut-off. Background Subgroup analysis of recent evidence suggests that undetectable hs-cTnT may exclude AMI at presentation. Methods In a cohort study, we prospectively enrolled patients with chest pain, evaluating them with standard troponin T and testing for hs-cTnT (Roche Diagnostics, Basel, Switzerland) at presentation. The primary outcome was a diagnosis of AMI. We also followed up patients for adverse events within 6 months. After subsequent clinical implementation of hs-cTnT, we again evaluated whether initially undetectable hs-cTnT ruled out a subsequent rise. Results Of 703 patients in the cohort study, 130 (18.5%) had AMI, none of whom initially had undetectable hs-cTnT (sensitivity: 100.0%, 95% confidence interval [CI]: 95.1% to 100.0%, negative predictive value: 100.0%, 95% CI: 98.1% to 100.0%). This strategy would rule out AMI in 27.7% of patients, 2 (1.0%) of whom died or had AMI within 6 months (1 periprocedural AMI, 1 noncardiac death). We evaluated this approach in an additional 915 patients in clinical practice. Only 1 patient (0.6%) with initially undetectable hs-cTnT had subsequent elevation (to 17 ng/l), giving a sensitivity of 99.8% (95% CI: 99.1% to 100.0%) and a negative predictive value of 99.4% (95% CI: 96.6% to 100.0%). Conclusions Undetectable hs-cTnT at presentation has very high negative predictive value, which may be considered to rule out AMI, identifying patients at low risk of adverse events. Pending further validation, this strategy may reduce the need for serial testing and empirical treatment, enabling earlier reassurance for patients and fewer unnecessary evaluations and hospital admissions.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX