An Unusual Complication From Hemostatic Packing to Control Bleeding During Cervical Mediastinoscopy and an Off-Pump Approach for the Later Exploration of the Superior Vena Caval Injury
Ist Teil von
The Annals of thoracic surgery, 2011-09, Vol.92 (3), p.1117-1118
Ort / Verlag
New York, NY: Elsevier Inc
Erscheinungsjahr
2011
Quelle
MEDLINE
Beschreibungen/Notizen
Cervical mediastinoscopy has been widely used and is considered a safe method for the histologic diagnosis and staging of many conditions. Hemorrhage still remains one of the main possible complications, and hemostasis is usually achieved without any further surgical intervention. We present a previously unreported complication of absorbable hemostatic gauze packing, which led to superior vena caval injury and multiple pulmonary emboli, necessitating further surgical repair with the use of a veno-venous shunt.