Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 15 von 215
Medicina oral, patología oral y cirugía bucal, 2011-08, Vol.16 (5), p.e664-e669
2011
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Predictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible
Ist Teil von
  • Medicina oral, patología oral y cirugía bucal, 2011-08, Vol.16 (5), p.e664-e669
Ort / Verlag
Spain
Erscheinungsjahr
2011
Quelle
MEDLINE
Beschreibungen/Notizen
  • Dental primary implant stability is considered essential in the success of the osseointegration process. The recent advent of the resonance frequency analysis (RFA) seems to effectively measure primary implant stability, although its relationship with implant survival has to be further established. Seventy patients with complete mandibular edentulism underwent dental implant rehabilitation by means of the placement of 68 dental implants within the interforaminal region and subsequent placement of an overdenture. Primary implant stability was measured by means of RFA and it was expressed in terms of implant stability quotient (ISQ) on the day of the implant insertion and at the time of the healing abutment placement in a conventional implant two-stage surgical procedure. Overall implant survival rate was 97.1% at the end of the follow-up period. The mean ISQ value for 3.75 and 4.25 mm diameter implants was 78.4 ± 5.46 and 80.83 ± 5.35 respectively, at the time of the implant placement; and 76.68 ± 4.34 and 78.22 ± 6.87 respectively, at the second surgical stage. No statistical differences were observed in relation to changes in mean ISQ value along the healing process. No statistical differences in terms of primary and secondary implant stability measured by RFA exists between 3.75 mm and 4.25 mm diameter implants in the conventional implant two-stage surgical procedure in patients with non-atrophied edentulous mandible being restored with an overdenture. Furthermore, no statistical association between RFA and the implant insertion torque was observed for endosseous dental implant placement at the first surgical stage.
Sprache
Englisch
Identifikatoren
ISSN: 1698-6946
eISSN: 1698-6946
DOI: 10.4317/medoral.16982
Titel-ID: cdi_proquest_miscellaneous_880718495

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX