Biomechanics of transfixation in pedicle screw instrumentation
Ist Teil von
  • Spine (Philadelphia, Pa. 1976), 1996-10, Vol.21 (19), p.2224-2229
Ort / Verlag
Philadelphia, PA: Lippincott
Erscheinungsjahr
1996
Quelle
MEDLINE
Beschreibungen/Notizen
  • The biomechanical role of transfixation in pedicle screw instrumentation was investigated using flexibility tests and finite element analyses. To assess the stabilizing effect of use and position of transfixators. Transfixation is common in pedicle screw instrumentation, however, its biomechanical role and optimal position are not completely understood. Specimens underwent nondestructive flexibility tests using a three-dimensional motion analysis system. Tests compared the intact spine with instrumentation with and without transfixators Rotational angles of the superior vertebra, resulting from the maximum moment of 6.4 Nm, were compared. Three-dimensional finite element models investigated transfixator position. Rotations of the superior vertebra were compared for cases with and without transfixators to determine the position providing the greatest stability. Biomechanical test showed that only axial rotational stability significantly improved with transfixators compared with instrumentation alone. Pimte element models predicted improvement in lateral bending and axial rotation with transfixators compared with the case with no transfixator. With one transfixator, the greatest improvement in axial rotation stability occurred with the transfixator at the proximal 1/4 position of the rods. When two transfixators were used, the optimal locations were with one transfixator in the middle and the second at the proximal 1/8 position. Transfixators improved the stabilizing effects of pedicle screw instrumentation. The greatest axial rotation stability was obtained with two transfixators; one in the middle and the other at the proximal 1/8 position of the longitudinal rods.
Sprache
Englisch
Identifikatoren
ISSN: 0362-2436
eISSN: 1528-1159
DOI: 10.1097/00007632-199610010-00009
Titel-ID: cdi_proquest_miscellaneous_78508763

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX