Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 11 von 18

Details

Autor(en) / Beteiligte
Titel
Euro-collins solution exacerbates lung injury in the setting of high-flow reperfusion
Ist Teil von
  • The Journal of thoracic and cardiovascular surgery, 1996-07, Vol.112 (1), p.111-116
Ort / Verlag
Philadelphia, PA: Mosby, Inc
Erscheinungsjahr
1996
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • Single-lung transplantation has been abandoned for the treatment of pulmonary hypertension by many centers because of overperfusion of the graft following implantation. Euro-Collins solution is currently used for lung preservation despite the vasoconstrictive effect of this intracellular-type solution. We hypothesized that high-flow reperfusion, alone or in combination with Euro-Collins–induced vasoconstriction, may cause lung dysfunction. Twenty-eight New Zealand White rabbit lungs were harvested and studied in an isolated, blood-perfused model of lung function after 4 hours of cold ischemia. Control lungs were preserved with 50 ml/kg cold saline solution flush and reperfused at either normal flow (60 ml/min) or high flow (120 ml/min). Experimental lungs were preserved with 50 ml/kg cold Euro-Collins solution and reperfused at normal or high flow rates. The arteriovenous oxygen gradient at the end of the 30-minute reperfusion period was significantly lower in the high-flow versus the low-flow experimental group (31.1 ± 4.2 vs 130.6 ± 41.6 mm Hg, p < 0.05). The pulmonary vascular resistance was increased in the high-flow groups and the experimental groups, with a statistically significant difference between low-flow experimental and control groups (64374.4 ± 5722.6 vs 37041.5 ± 2110.9 dynes•sec•cm –5, p < 0.001). The percentage decrease in dynamic airway compliance in the high-flow experimental group was markedly different from that in the high-flow control group (–51% ± 13.3% vs –10.15% ± 3.4%, p < 0.05). Similarly, the wet/dry ratio of the lungs in the high-flow experimental group (13.92 ± 2.32) was significantly greater than that in the low-flow experimental group (6.27 ± 0.19, p < 0.01) and than that in the high-flow control group (5.88 ± 0.23, p < 0.001). These data demonstrate that high-flow reperfusion and preservation with Euro-Collins solution are deleterious to lung function, both individually and in combination, in an ex vivo rabbit lung model. Lung preservation with Euro-Collins solution may not be optimal when high-flow reperfusion is anticipated, as in the setting of unilateral lung transplantation for pulmonary hypertension. (J T horac C ardiovasc S urg 1996;112:111-6)

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX