Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 19 von 260
Journal of ultrasound in medicine, 2010-10, Vol.29 (10), p.1469-1474
2010

Details

Autor(en) / Beteiligte
Titel
Spatiotemporal image correlation using high-definition flow: a new method for assessing ovarian vascularization
Ist Teil von
  • Journal of ultrasound in medicine, 2010-10, Vol.29 (10), p.1469-1474
Ort / Verlag
England
Erscheinungsjahr
2010
Link zum Volltext
Quelle
Wiley Online Library All Journals
Beschreibungen/Notizen
  • The purpose of this study was to describe a new method for assessing ovarian vascularization using spatiotemporal image correlation (STIC)-high-definition flow (HDF). Thirty healthy premenopausal fertile women were assessed in the follicular part of the menstrual cycle by transvaginal sonography. A 4-dimensional STIC-HDF volume was obtained from the nondominant ovary to assess 3-dimensional (3D) vascular indices (vascularization index [VI] and flow index [FI]) during one cardiac cycle in each women. Using 1-cm(3) spherical sampling, we calculated the VI and FI from the most vascularized part of the ovarian stroma at two different moments of the cardiac cycle (systole and diastole). System settings were kept constant for all of the patients (pulse repetition frequency, 0.9 kHz; gain, 0.8; and depth, 40 mm). We calculated the VI and FI ratios between systole and diastole. The mean VI during systole (11.485%; SD, 6.7%) was significantly higher than during diastole (8.653%; SD, 5.6%; P < .0001). The mean FI values during systole (47.799 [unitless]; SD, 5.8) and diastole (47.791; SD, 6.0) were nearly identical (P = .993). The VI ratio was 1.35 (95% confidence interval, 1.28-1.42), which means that the mean VI was 35% higher during systole compared to diastole, whereas the FI during systole and diastole remained constant (FI ratio, 1.00; 95% confidence interval, 0.96-1.04). There was a high correlation between VI values during systole and diastole (r(2) = 0.94), whereas this correlation was weaker for the FI (r(2) = 0.45). The STIC-HDF method allows assessment of 3D vascular indices throughout the cardiac cycle. Vascularization index calculation is affected by the moment of the cardiac cycle during which the measurement is taken. However, it seems that FI calculation is not affected by the cardiac cycle in the normal nondominant ovary.
Sprache
Englisch
Identifikatoren
ISSN: 0278-4297
eISSN: 1550-9613
DOI: 10.7863/jum.2010.29.10.1469
Titel-ID: cdi_proquest_miscellaneous_755969002

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX