Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 16 von 326

Details

Autor(en) / Beteiligte
Titel
Health Care-Associated Bloodstream Infections Associated with Negative- or Positive-Pressure or Displacement Mechanical Valve Needleless Connectors
Ist Teil von
  • Clinical infectious diseases, 2009-12, Vol.49 (12), p.1821-1827
Ort / Verlag
Oxford: The University of Chicago Press
Erscheinungsjahr
2009
Quelle
Oxford Journals 2020 Medicine
Beschreibungen/Notizen
  • Background. Health care-associated, central venous catheter-related bloodstream infections (HA-BSIs) are a major cause of morbidity and mortality. Needleless connectors (NCs) are an important component of the intravenous system. NCs initially were introduced to reduce health care worker needlestick injuries, yet some of these NCs may increase HA-BSI risk. Methods. We compared HA-BSI rates on wards or intensive care units (ICUs) at 5 hospitals that had converted from split septum (SS) connectors or needles to mechanical valve needleless connectors (MV-NCs). The hospitals (16 ICUs, 1 entire hospital, and 1 oncology unit; 3 hospitals were located in the United States, and 2 were located in Australia) had conducted HA-BSI surveillance using Centers for Disease Control and Prevention definitions during use of both NCs. HA-BSI rates and prevention practices were compared during the pre-MV period, MV period, and post-MV period. Results. The HA-BSI rate increased in all ICUs and wards when SS-NCs were replaced by MV-NCs. In the 16 ICUs, the HA-BSI rate increased significantly when SS-NCs or needles were replaced by MV-NCs (6.15 vs 9.49 BSIs per 1000 central venous catheter [CVC]-days; relative risk, 1.54; 95% confidence interval, 1.37–1.74; P<.001). The 14 ICUs that switched back to SS-NCs had significant reductions in their BSI rates (9.49 vs 5.77 BSIs per 1000 CVC-days; relative risk, 1.65; 95% confidence interval, 1.38–1.96; P<.001). BSI infection prevention strategies were similar in the pre-MV and MV periods. Conclusions. We found strong evidence that MV-NCs were associated with increased HA-BSI rates, despite similar BSI surveillance, definitions, and prevention strategies. Hospital personnel should monitor their HA-BSI rates and, if they are elevated, examine the role of newer technologies, such as MV-NCs.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX