Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 22 von 310

Details

Autor(en) / Beteiligte
Titel
Comparison of baroreflex sensitivity determined by cross-spectral analysis at respiratory and 0.1 Hz frequencies in man
Ist Teil von
  • Physiological research, 2010, Vol.59 Suppl 1, p.S103-S111
Ort / Verlag
Czech Republic: Institute of Physiology
Erscheinungsjahr
2010
Quelle
MEDLINE
Beschreibungen/Notizen
  • Non-invasive methods of determination of baroreflex sensitivity (BRS, ms/mmHg) are based on beat-to-beat systolic blood pressure and inter-beat interval recording. Sequential methods and spectral methods at spontaneous breathing include transient superposition of breathing and 0.1 Hz rhythms. Previously, a cross-spectral method of analysis was used, at constant breathing rate using a metronome set at 0.33 Hz, enabling separate determination of BRS at 0.1 Hz (BRS(0.1Hz)) and respiratory rhythms (BRS(0.33Hz)). The aim of the present study was to evaluate the role of breathing in the spectral method of BRS determination with respect to age and hypertension. Such information would be important in evaluation of BRS at pathological conditions associated with extremely low BRS levels. Blood pressure was recorded by Finapres (5 minutes, controlled breathing at 0.33 Hz) in 118 healthy young subjects (YS: mean age 21.0+/-1.3 years), 26 hypertensive patients (HT: mean age 48.6+/-10.3 years) with 26 age-matched controls (CHT: mean age 46.3+/-8.6 years). A comparison of BRS(0.1Hz) and BRS(0.33Hz) was made. Statistically significant correlations were found between BRS(0.1Hz) and BRS(0.33Hz) in all groups: YS: r=0.52, p<0.01, HT: r=0.47, p<0.05, and CHT: r=0.70, p<0.01. The regression equations indicated the existence of a breathing-dependent component unrelated to BRS (YS: BRS(0.33Hz)=2.63+1.14*BRS(0.1Hz); HT: BRS(0.33Hz)=3.19+0.91*BRS(0.1Hz); and CHT: BRS(0.33Hz)=1.88+ +1.01*BRS(0.1Hz); differences between the slopes and the slope of identity line were insignificant). The ratios of BRS(0.1Hz) to BRS(0.33Hz) were significantly lower than 1 (p<0.01) in all groups (YS: 0.876+/-0.419, HT: 0.628+/-0.278, and CHT: 0.782+/-0.260). Thus, BRS evaluated at the breathing rate overestimates the real baroreflex sensitivity. This is more pronounced at low values of BRS, which is more important in patients with pathologic low BRS. For diagnostic purposes we recommend the evaluation of BRS at the frequency of 0.1 Hz using metronome-controlled breathing at a frequency that is substantially higher than 0.1 Hz and is not a multiple of 0.1 Hz to eliminate respiratory baroreflex-non-related influence and resonance effect on heart rate fluctuations.
Sprache
Englisch
Identifikatoren
ISSN: 0862-8408
eISSN: 1802-9973
DOI: 10.33549/physiolres.932009
Titel-ID: cdi_proquest_miscellaneous_733979199

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX