UNIVERSI
TÄ
TS-
BIBLIOTHEK
P
ADERBORN
Anmelden
Menü
Menü
Start
Hilfe
Blog
Weitere Dienste
Neuerwerbungslisten
Fachsystematik Bücher
Erwerbungsvorschlag
Bestellung aus dem Magazin
Fernleihe
Einstellungen
Sprache
Deutsch
Deutsch
Englisch
Farbschema
Hell
Dunkel
Automatisch
Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist
gegebenenfalls
nur via VPN oder Shibboleth (DFN-AAI) möglich.
mehr Informationen...
Universitätsbibliothek
Katalog
Suche
Details
Zur Ergebnisliste
Ergebnis 7 von 217
Datensatz exportieren als...
BibTeX
How does blood oxygen level-dependent (BOLD) contrast correlate with oxygen partial pressure (pO2) inside tumors?
Magnetic resonance in medicine, 2002-12, Vol.48 (6), p.980-986
Baudelet, Christine
Gallez, Bernard
2002
Volltextzugriff (PDF)
Details
Autor(en) / Beteiligte
Baudelet, Christine
Gallez, Bernard
Titel
How does blood oxygen level-dependent (BOLD) contrast correlate with oxygen partial pressure (pO2) inside tumors?
Ist Teil von
Magnetic resonance in medicine, 2002-12, Vol.48 (6), p.980-986
Ort / Verlag
New York: Wiley Subscription Services, Inc., A Wiley Company
Erscheinungsjahr
2002
Quelle
Wiley-Blackwell Journals
Beschreibungen/Notizen
Blood oxygen level‐dependent (BOLD) contrast‐based functional MRI (fMRI) has been reported as a method to assess the evolution of tumor oxygenation after hyperoxic treatments, because of its sensitivity to changes in blood flow and deoxyhemoglobin content. However a number of questions remain: 1) In view of tumor heterogeneity, how good is the correlation between the MR parameters in gradient‐echo imaging (signal intensity (SI) or effective transverse relaxation time (T *2)) and local tumor oxygen partial pressure (pO2)? 2) Is the magnitude of the change in SI or T *2 a quantitative marker for variation in pO2? 3) Is initial T *2 a good marker for initial pO2? To address these questions, murine tumors were imaged during respiratory challenges at 4.7 Tesla, using fiber‐optic microprobes to simultaneously acquire tumor pO2 and erythrocyte flux. The BOLD signal response (SI and T *2) was temporally correlated with changes in pO2. However, the magnitude of the signal bore no absolute relation to pO2 across tumors, i.e., a given change in SI corresponded to a 25 mmHg pO2 change in one tumor, but to a 100 mmHg change in another. The initial T *2 value did not reliably predict tumor oxygenation at the beginning of the experiment. In conclusion, the major advantages of the technique include noninvasiveness, high spatial resolution, and real‐time detection of pO2 fluctuations. Information afforded by the BOLD imaging technique is qualitative in nature and may be combined with other techniques capable of providing an absolute measure of pO2. Magn Reson Med 48:980–986, 2002. © 2002 Wiley‐Liss, Inc.
Sprache
Englisch
Identifikatoren
ISSN: 0740-3194
eISSN: 1522-2594
DOI: 10.1002/mrm.10318
Titel-ID: cdi_proquest_miscellaneous_72739324
Format
–
Schlagworte
Animals
,
Biological and medical sciences
,
BOLD
,
Contrast Media
,
correlation
,
Disease Models, Animal
,
Electron Spin Resonance Spectroscopy
,
Fibrosarcoma - diagnosis
,
Fibrosarcoma - metabolism
,
Image Enhancement
,
Image Processing, Computer-Assisted
,
Investigative techniques, diagnostic techniques (general aspects)
,
Magnetic Resonance Imaging
,
Male
,
Medical sciences
,
Mice
,
Mice, Inbred C3H
,
Miscellaneous. Technology
,
Oxygen - blood
,
Oxygen - metabolism
,
Oxygen Consumption
,
pO2
,
Pressure
,
Radiodiagnosis. Nmr imagery. Nmr spectrometry
,
Regional Blood Flow
,
Sensitivity and Specificity
,
tumor
,
T 2
Weiterführende Literatur
Empfehlungen zum selben Thema automatisch vorgeschlagen von
bX