Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 5 von 35
Journal of the American Society of Nephrology, 2007-08, Vol.18 (8), p.2294-2302
2007
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Peritoneal changes after exposure to sterile solutions by catheter
Ist Teil von
  • Journal of the American Society of Nephrology, 2007-08, Vol.18 (8), p.2294-2302
Ort / Verlag
Hagerstown, MD: Lippincott Williams & Wilkins
Erscheinungsjahr
2007
Quelle
MEDLINE
Beschreibungen/Notizen
  • Most current animal models that are used to study effects of long-term peritoneal exposure to dialysis solutions use an indwelling catheter for daily injections. It was hypothesized that the presence of a foreign body in the peritoneal cavity (PC) might alter the inflammatory response to the solutions and that the response would depend on exposure duration. For addressing these, long-term injections were carried out for 2 to 8 wk in 90 Sprague-Dawley rats: 40 via a subcutaneous port connected to a silicone catheter tunneled to the PC, 40 via direct needle injection, and 10 noninjected, age-control rats. Daily volumes were 30 to 40 ml of filter-sterilized, bicarbonate-buffered solutions that contained 4% dextrose. After 2, 4, 6, and 8 wk, anesthetized rats underwent transport experiments with a chamber affixed to the abdominal wall to determine mass transfer coefficients of mannitol (MTC(mannitol)) and albumin (MTC(BSA)), osmotic filtration flux (J(osm)), and hydrostatic pressure-driven flux. After the rats were killed, tissues were collected for measurement of peritoneal thickness, vascular density, and immunohistochemical staining. ANOVA demonstrated significant (P < 0.01) differences in thickness, vessel density, MTC(mannitol), and MTC(BSA) among the groups at the various time intervals and in overall means. Differences among the groups were less pronounced for hydrostatic pressure-driven flux and J(osm). Vessel density, MTC(mannitol), MTC(BSA), and J(osm) were dependent on injection duration (P < 0.01). There were marked differences between the needle injection and catheter injection groups at various intervals in the expression of three cytokines. It is concluded that the histologic and functional response depends on the duration of injection with animals that are exposed for as little as 2 wk demonstrating alterations. These findings confirm the hypothesis that the presence of a PC catheter increases inflammatory response to sterile solutions as evidenced by the structural and functional changes in the peritoneal barrier.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX