Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 13 von 122

Details

Autor(en) / Beteiligte
Titel
High-frequency oscillatory ventilation reduces lung inflammation : a large-animal 24-h model of respiratory distress
Ist Teil von
  • Intensive care medicine, 2007-08, Vol.33 (8), p.1423-1433
Ort / Verlag
Heidelberg: Springer
Erscheinungsjahr
2007
Quelle
SpringerLink
Beschreibungen/Notizen
  • High-frequency oscillatory ventilation (HFOV) may reduce ventilator-induced lung injury in experimental neonatal respiratory distress. However, these data permit no conclusions for large animals or adult patients with acute respiratory distress syndrome (ARDS), because in neonates higher frequencies and lower amplitudes can be used, resulting in lower tidal volumes (VT) and airway pressures. The aim of this study was to compare gas exchange, lung histopathology and inflammatory cytokine expression during lung-protective pressure-controlled ventilation (PCV) and HFOV in a long-term large-animal model of ARDS. Prospective, randomized, controlled pilot study. University animal laboratory. Sixteen female pigs (55.3 +/- 3.9 kg). After induction of ARDS by repeated lavage, the animals were randomly assigned to PCV (VT = 6 ml/kg) and HFOV (6 Hz). After lung injury, a standardised lung recruitment was performed in both groups, and ventilation was continued for 24 h. After lung recruitment sustained improvements in the oxygenation index were observed in both groups. The mean airway pressure (mPaw) was significantly lower in the HFOV group during the experiment (p < 0.01). Histologically, lung inflammation was significantly ameliorated in the HFOV group (p < 0.05). The messenger RNA expression of IL-1-beta in lung tissue was significantly lower in the HFOV-treated animals (p < 0.01). These data suggest that HFOV compared with conventional lung-protective ventilation can reduce lung inflammation in a large-animal 24-h model of ARDS. Furthermore, it was shown that lung recruitment leads to sustained improvements in gas exchange with a significantly lower mPaw when HFOV is used.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX