UNIVERSI
TÄ
TS-
BIBLIOTHEK
P
ADERBORN
Anmelden
Menü
Menü
Start
Hilfe
Blog
Weitere Dienste
Neuerwerbungslisten
Fachsystematik Bücher
Erwerbungsvorschlag
Bestellung aus dem Magazin
Fernleihe
Einstellungen
Sprache
Deutsch
Deutsch
Englisch
Farbschema
Hell
Dunkel
Automatisch
Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist
gegebenenfalls
nur via VPN oder Shibboleth (DFN-AAI) möglich.
mehr Informationen...
Universitätsbibliothek
Katalog
Suche
Details
Zur Ergebnisliste
Ergebnis 19 von 1037
Datensatz exportieren als...
BibTeX
Perfusion-corrected mapping of cardiac regional blood volume in rats in vivo
Magnetic resonance in medicine, 1999-09, Vol.42 (3), p.500-506
Kahler, E.
Waller, C.
Rommel, E.
Belle, V.
Hiller, K.H.
Voll, S.
Bauer, W.R.
Haase, A.
1999
Volltextzugriff (PDF)
Details
Autor(en) / Beteiligte
Kahler, E.
Waller, C.
Rommel, E.
Belle, V.
Hiller, K.H.
Voll, S.
Bauer, W.R.
Haase, A.
Titel
Perfusion-corrected mapping of cardiac regional blood volume in rats in vivo
Ist Teil von
Magnetic resonance in medicine, 1999-09, Vol.42 (3), p.500-506
Ort / Verlag
New York: John Wiley & Sons, Inc
Erscheinungsjahr
1999
Quelle
Wiley Online Library - AutoHoldings Journals
Beschreibungen/Notizen
Measurement of regional blood volume (RBV) in the myocardium in vivo is important for the assessment of tissue viability and function. The method in this work is based on the acquisition of a T1 map before and after intravascular contrast agent application. It is known that this method is influenced by perfusion that causes an overestimation of RBV values. In order to solve this problem, the new method is proposed which acquires T1 maps with slice selective inversion pulses. Due to blood flow nonexcited spins enter the detection slice, which leads to an acceleration of the relaxation time. A model that divides tissue into two compartments is adapted to slice selective inversion in order to derive a simple expression for perfusion‐corrected RBV. The aim of the study is to demonstrate the feasibility and accuracy of this technique for quantification of RBV in rat myocardium in vivo. RBV maps were obtained for five rats, and the reproducibility was determined by repeating the experiment several times. A mean RBV value of 12.8 ± 0.7% (v/v) over all animals was obtained in the myocardium. The results were compared with RBV maps obtained with perfusion‐sensitive RBV imaging in the same five rats and with first‐pass RBV studies. In order to demonstrate the strength of the new method the vasodilator adenosine was administered and alterations in microcirculation were imaged. Magn Reson Med 42:500–506, 1999. © 1999 Wiley‐Liss, Inc.
Sprache
Englisch
Identifikatoren
ISSN: 0740-3194
eISSN: 1522-2594
DOI: 10.1002/(SICI)1522-2594(199909)42:3<500::AID-MRM12>3.0.CO;2-3
Titel-ID: cdi_proquest_miscellaneous_70011400
Format
–
Schlagworte
Adenosine - administration & dosage
,
Albumins
,
Animals
,
Biological and medical sciences
,
Blood Flow Velocity
,
Blood Volume
,
Cardiovascular system
,
Contrast Media
,
Coronary Circulation - physiology
,
Gadolinium DTPA
,
Image Processing, Computer-Assisted
,
Investigative techniques, diagnostic techniques (general aspects)
,
Least-Squares Analysis
,
Magnetic Resonance Imaging
,
Male
,
Mathematics
,
Medical sciences
,
Microcirculation - physiology
,
Models, Cardiovascular
,
myocardium
,
Myocardium - metabolism
,
perfusion
,
quantitative MRI
,
Radiodiagnosis. Nmr imagery. Nmr spectrometry
,
Rats
,
Rats, Wistar
,
RBV
,
T1 imaging
,
Vasodilator Agents - administration & dosage
Weiterführende Literatur
Empfehlungen zum selben Thema automatisch vorgeschlagen von
bX