Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 4 von 4

Details

Autor(en) / Beteiligte
Titel
Antimony concentrations in nodal tissue can confirm sentinel node identity
Ist Teil von
  • Modern pathology, 2004-10, Vol.17 (10), p.1191-1197
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2004
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • The sentinel node biopsy procedure is a highly accurate method of staging patients with cutaneous melanoma and the tumor-harboring status of sentinel nodes is the most important prognostic factor. For the procedure to provide accurate prognostic information, however, it is essential that ‘true’ sentinel nodes are removed and examined thoroughly. A technique to confirm sentinel node identity may reduce the false-negative rate of the procedure. We have found that antimony (originating from the antimony sulfide colloid used for preoperative lymphoscintigraphy in our institution) can be measured in tissue sections of sentinel nodes using inductively coupled plasma mass spectrometry. The aims of this study were to determine whether antimony concentrations can be used to confirm that removed sentinel nodes are ‘true’ sentinel nodes and to differentiate sentinel nodes from nonsentinel nodes. In all, 24 patients who had both a tumor-positive sentinel node and a tumor-negative nonsentinel node removed from one regional node field during the same operation, were identified. Tissue sections (50 μm) thick were cut from archival paraffin blocks of each of the sentinel nodes and nonsentinel nodes. Antimony concentrations in the tissue sections were measured using inductively coupled plasma mass spectrometry. The median and mean concentrations of antimony in parts per billion were 0.526 and 1.198, respectively (range 0.020–7.596) in the sentinel nodes, and 0.043 and 0.123 (range 0–0.800) in the nonsentinel nodes (P=0.004). In four of the 24 pairs, both the presumed sentinel nodes and the nonsentinel nodes had very low antimony levels (less than 0.18 parts per billion), suggesting that nodes designated as sentinel nodes may not have been ‘true’ sentinel nodes. It is concluded that determination of antimony concentrations within sentinel nodes using the highly sensitive method of inductively coupled plasma mass spectrometry can confirm the identity of sentinel nodes and validate the sentinel node technique.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX