Development and application of an excitation ratiometric optical pH sensor for bioprocess monitoring
Ist Teil von
  • Biotechnology progress, 2008-11, Vol.24 (6), p.1393-1401
Ort / Verlag
Hoboken: Wiley Subscription Services, Inc., A Wiley Company
Erscheinungsjahr
2008
Link zum Volltext
Quelle
Wiley Online Library - AutoHoldings Journals
Beschreibungen/Notizen
  • The development of a fluorescent excitation ratiometric pH sensor (AHQ‐PEG) using a novel allylhydroxyquinolinium (AHQ) derivative copolymerized with polyethylene glycol dimethacrylate (PEG) is described. The AHQ‐PEG sensor film is shown to be suitable for real‐time, noninvasive, continuous, online pH monitoring of bioprocesses. Optical ratiometric measurements are generally more reliable, robust, inexpensive, and insensitive to experimental errors such as fluctuations in the source intensity and fluorophore photobleaching. The sensor AHQ‐PEG in deionized water was shown to exhibit two excitation maxima at 375 and 425 nm with a single emission peak at 520 nm. Excitation spectra of AHQ‐PEG show a decrease in emission at the 360 nm excitation and an increase at the 420 nm excitation with increasing pH. Accordingly, the ratio of emission at 420:360 nm excitation showed a maximum change between pH 5 and 8 with an apparent pKa of 6.40. The low pKa value is suitable for monitoring the fermentation of most industrially important microorganisms. Additionally, the AHQ‐PEG sensor was shown to have minimal sensitivity to ionic strength and temperature. Because AHQ is covalently attached to PEG, the film shows no probe leaching and is sterilizable by steam and alcohol. It shows rapid (∼2 min) and reversible response to pH over many cycles without any photobleaching. Subsequently, the AHQ‐PEG sensor film was tested for its suitability in monitoring the pH of S. cereviseae (yeast) fermentation. The observed pH using AHQ‐PEG film is in agreement with a conventional glass pH electrode. However, unlike the glass electrode, the present sensor is easily adaptable to noninvasive monitoring of sterilized, closed bioprocess environments without the awkward wire connections that electrodes require. In addition, the AHQ‐PEG sensor is easily miniaturized to fit in microwell plates and microbioreactors for high‐throughput cell culture applications.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX