Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 25 von 81

Details

Autor(en) / Beteiligte
Titel
Experiences when using different EHMR models: Implications for different designs and meeting user expectations
Ist Teil von
  • American journal of infection control, 2024-08
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2024
Quelle
Elsevier ScienceDirect Journals
Beschreibungen/Notizen
  • New elastomeric half-mask respirator (EHMR) models without exhalation valves (EVs) or with exhalation valve filters (EVFs) are facilitating expanded use in health settings to reduce workers’ exposure to airborne hazards while acting as source control to prevent pathogen spread. The physical comfort of new models has not been assessed in comparison to previously used EHMRs with EVs. Researchers assessed 1,962 health care and emergency medical service personnels’ self-reported adverse experiences from 2 cohorts while wearing EHMR models with EVs (cohort 1, n = 1,080) and without EVs or with EVFs (cohort 2, n = 882). Fisher exact test identified differences between the cohorts accounting for organizational factors when possible. Cohort 1 respondents experienced communication challenges and discomfort when wearing the EHMR > 1 hour statistically significantly more often than cohort 2. Cohort 2 respondents reported statistically significantly more instances of difficulty breathing, moisture buildup, being uncomfortable to wear < 1 hour, and being uncomfortably warm. Discomfort is prevalent among end users and more often among those wearing EHMRs without an EV/with an EVF. As EHMR research and development advances, prevalence in use may increase for emergency and routine situations. Organizations may not only need guidance about respirator selection but also model-specific selection. •EHMRs are suitable for use in a range of healthcare and emergency response roles.•Occupations may experience different types of PPE interference based on tasks.•Users from organizations with EHMR experience were less likely to express discomfort.•Cohort 2 experienced excess warmth and moisture buildup 2 times more than cohort 1.•EHMRs may be stockpiled for routine use and emergency preparedness and response.
Sprache
Englisch
Identifikatoren
ISSN: 0196-6553, 1527-3296
eISSN: 1527-3296
DOI: 10.1016/j.ajic.2024.08.019
Titel-ID: cdi_proquest_miscellaneous_3097850153

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX