Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 10 von 438
Journal of environmental radioactivity, 2024-09, Vol.278, p.107491, Article 107491
2024
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
A tomographic spatial-unfolding method for Compton gamma imaging measurements
Ist Teil von
  • Journal of environmental radioactivity, 2024-09, Vol.278, p.107491, Article 107491
Ort / Verlag
Elsevier Ltd
Erscheinungsjahr
2024
Quelle
Access via ScienceDirect (Elsevier)
Beschreibungen/Notizen
  • An advanced spatial-unfolding technique capable of reconstructing the activity distribution within an exclusion zone from Compton gamma imager measurements taken outside of it is introduced. Although the method is generally applicable to extended sources, we demonstrate it here on a calibrated Cs-137 point source through Monte Carlo simulation studies as well as with measurements made using a Silicon Compton Telescope for Safety and Security (SCoTSS) gamma imager. For synthetic data the method accurately reconstructs the total activity contained within the mapped zone of interest, even when the size of the basis elements used to reconstruct the activity distribution is larger than the source itself. For experimental data, the method reliably located the source but underestimated its activity by up to 17%. This is accurate enough for real-world security applications. The underestimation is likely due to effects not yet included in the simulated response of the detector. The method has widespread applicability in the radiological/nuclear safety and security field, particularly for scenarios in which a threat material or contaminated area lies within a no-entry or no-fly zone. •A spatial-unfolding technique applicable to Compton gamma imaging is introduced.•Method is validated with Monte Carlo and experimental Cs-137 point source data.•Source is reliably localized but the experimental activity is underestimated by 17%.•Method is applicable to sources extending over large areas at great distance.•Method has applicability in the radiological/nuclear safety and security field.
Sprache
Englisch
Identifikatoren
ISSN: 0265-931X, 1879-1700
eISSN: 1879-1700
DOI: 10.1016/j.jenvrad.2024.107491
Titel-ID: cdi_proquest_miscellaneous_3080635181

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX