Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 6 von 16

Details

Autor(en) / Beteiligte
Titel
Deep Learning-Based Approach for Identifying and Measuring Focal Liver Lesions on Contrast-Enhanced MRI
Ist Teil von
  • Journal of magnetic resonance imaging, 2024-06
Ort / Verlag
United States
Erscheinungsjahr
2024
Quelle
Wiley Online Library
Beschreibungen/Notizen
  • The number of focal liver lesions (FLLs) detected by imaging has increased worldwide, highlighting the need to develop a robust, objective system for automatically detecting FLLs. To assess the performance of the deep learning-based artificial intelligence (AI) software in identifying and measuring lesions on contrast-enhanced magnetic resonance imaging (MRI) images in patients with FLLs. Retrospective. 395 patients with 1149 FLLs. The 1.5 T and 3 T scanners, including T1-, T2-, diffusion-weighted imaging, in/out-phase imaging, and dynamic contrast-enhanced imaging. The diagnostic performance of AI, radiologist, and their combination was compared. Using 20 mm as the cut-off value, the lesions were divided into two groups, and then divided into four subgroups: <10, 10-20, 20-40, and ≥40 mm, to evaluate the sensitivity of radiologists and AI in the detection of lesions of different sizes. We compared the pathologic sizes of 122 surgically resected lesions with measurements obtained using AI and those made by radiologists. McNemar test, Bland-Altman analyses, Friedman test, Pearson's chi-squared test, Fisher's exact test, Dice coefficient, and intraclass correlation coefficients. A P-value <0.05 was considered statistically significant. The average Dice coefficient of AI in segmentation of liver lesions was 0.62. The combination of AI and radiologist outperformed the radiologist alone, with a significantly higher detection rate (0.894 vs. 0.825) and sensitivity (0.883 vs. 0.806). The AI showed significantly sensitivity than radiologists in detecting all lesions <20 mm (0.848 vs. 0.788). Both AI and radiologists achieved excellent detection performance for lesions ≥20 mm (0.867 vs. 0.881, P = 0.671). A remarkable agreement existed in the average tumor sizes among the three measurements (P = 0.174). AI software based on deep learning exhibited practical value in automatically identifying and measuring liver lesions. Stage 2.
Sprache
Englisch
Identifikatoren
eISSN: 1522-2586
DOI: 10.1002/jmri.29404
Titel-ID: cdi_proquest_miscellaneous_3064141041
Format

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX