Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 13 von 45

Details

Autor(en) / Beteiligte
Titel
Exo I-based cyclic digestion coupled with synergistic enhancement strategy for integrating dual-mode optical aptasensor platform
Ist Teil von
  • Talanta (Oxford), 2024-08, Vol.276, p.126286, Article 126286
Ort / Verlag
Netherlands: Elsevier B.V
Erscheinungsjahr
2024
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • The improvement of dual-mode techniques was of particular interest to researchers, which might enhance the detection performance and applicability. Here, a dual-mode optical aptasensor (DO-aptasensor) platform based on exonuclease I (Exo I) cyclic digestion and synergistic enhancement strategy had proposed for zearalenone (ZEN). Following the preparation of dumbbell-shaped signal probe, the Exo I-based cyclic digestion amplification performed, and then the synergistic enhancement effect carried out to achieve the Poly-HRP-based colorimetry and FAM-SGI-based fluorescence. The efficient homogeneous system realized through the magnetic separation, while the signal interference further eliminated by the graphene oxide (GO). The LOD values were as low as 0.067 ng mL−1 for colorimetry mode and 0.009 ng mL−1 for fluorescence mode, which reduced 23-fold and 172-fold than ELASA by same ZEN-Apt. This promising platform gave rise to a dual-mode optical readout, improved sensitivity and positively correlated detection. Meanwhile, the DO-aptasensor also exhibited the acceptable specificity, desirable reliability and excellent practicability. This novel avenue of aptasensor platform hold great potential for dual-mode optical monitoring of other targets, which can further expand the application scope of Exo I-based signal amplification and synergistic enhancement effect. [Display omitted] •Dual-mode aptasensor: Poly-HRP-based colorimetry and FAM-SGI-based fluorescence.•Efficient homogeneous system through MB, and minimized signal interference by GO.•Positively correlated LOD were as low as 0.067 ng mL−1 and 0.009 ng mL−1.•Sensitivity, reliability and practicability had been well exhibited.•Application of cyclic digestion and synergistic enhancement could broaden.
Sprache
Englisch
Identifikatoren
ISSN: 0039-9140, 1873-3573
eISSN: 1873-3573
DOI: 10.1016/j.talanta.2024.126286
Titel-ID: cdi_proquest_miscellaneous_3059258984

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX