Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 6 von 10

Details

Autor(en) / Beteiligte
Titel
Ultrafast 3-D Transcutaneous Super Resolution Ultrasound Using Row-Column Array Specific Coherence-Based Beamforming and Rolling Acoustic Sub-aperture Processing: In Vitro, in Rabbit and in Human Study
Ist Teil von
  • Ultrasound in medicine & biology, 2024-07, Vol.50 (7), p.1045-1057
Ort / Verlag
England: Elsevier Inc
Erscheinungsjahr
2024
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • This study aimed to realise 3-D super-resolution ultrasound imaging transcutaneously with a row-column array which has far fewer independent electronic channels and a wider field of view than typical fully addressed 2-D matrix arrays. The in vivo image quality of the row-column array is generally poor, particularly when imaging non-invasively. This study aimed to develop a suite of image formation and post-processing methods to improve image quality and demonstrate the feasibility of ultrasound localisation microscopy using a row-column array, transcutaneously on a rabbit model and in a human. To achieve this, a processing pipeline was developed which included a new type of rolling window image reconstruction, which integrated a row-column array specific coherence-based beamforming technique with acoustic sub-aperture processing. This and other processing steps reduced the ‘secondary’ lobe artefacts, and noise and increased the effective frame rate, thereby enabling ultrasound localisation images to be produced. Using an in vitro cross tube, it was found that the procedure reduced the percentage of ‘false’ locations from ∼26% to ∼15% compared to orthogonal plane wave compounding. Additionally, it was found that the noise could be reduced by ∼7 dB and the effective frame rate was increased to over 4000 fps. In vivo, ultrasound localisation microscopy was used to produce images non-invasively of a rabbit kidney and a human thyroid. It has been demonstrated that the proposed methods using a row-column array can produce large field of view super-resolution microvascular images in vivo and in a human non-invasively.
Sprache
Englisch
Identifikatoren
ISSN: 0301-5629, 1879-291X
eISSN: 1879-291X
DOI: 10.1016/j.ultrasmedbio.2024.03.020
Titel-ID: cdi_proquest_miscellaneous_3050942261

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX