Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 10 von 257

Details

Autor(en) / Beteiligte
Titel
Custom-Made Implant Fabrication for Chin Augmentation Using Piled-Up Expanded Polytetrafluoroethylene Sheets: An Innovative Surgical Technique and Literature Review
Ist Teil von
  • Aesthetic plastic surgery, 2024-03, Vol.48 (11), p.2018-2024
Ort / Verlag
New York: Springer US
Erscheinungsjahr
2024
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Background Alloplastic chin augmentation is the most common esthetic surgical treatment to reshape the chin. However, factory-made chin implants are typically standardized rather than custom-made and have potential to cause complications. Although the fabrication of custom-made implants by using computer-assisted planning and 3D-printing technology has become widespread, the process has several disadvantages, including long preoperative prosthesis preparation times, high costs, and unsuitability for patients with asymmetric chins or those who undergo combined mandibuloplasty before implant placement. The present study developed an innovative chin augmentation technique involving stacked expanded polytetrafluoroethylene (e-PTFE) sheets that is suitable for most patients and has minimal side effects. Materials and Methods A retrospective review of a single surgeon’s experience was performed over a 2 year period for patients who underwent a procedure involving piled-up e-PTFE sheets for alloplastic chin augmentation. This study analyzed the outcomes, complications (temporary nerve numbness, wound infection, hematoma formation, and implant displacement), and patient satisfaction during follow-up. Results Between January 2018 and December 2020, 38 patients underwent the procedure involving piled-up e-PTFE sheets for alloplastic chin augmentation. Six patients (15.8%) experienced nerve-related temporary numbness, and one (2.6%) experienced wound infection. None had developed major complications such as implant displacement or wound infection at follow-up. Moreover, the patients demonstrated a high level of satisfaction with the surgical results. Conclusion Piled-up e-PTFE sheets can be used to produce custom-fit porous polyethylene chin implants that result in minimal complications and a very high satisfaction rate. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Sprache
Englisch
Identifikatoren
ISSN: 0364-216X
eISSN: 1432-5241
DOI: 10.1007/s00266-024-03918-1
Titel-ID: cdi_proquest_miscellaneous_2968921015

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX