Fluorescein-stained confocal laser endomicroscopy versus conventional frozen section for intraoperative histopathological assessment of intracranial tumors
Ist Teil von
  • Neuro-oncology (Charlottesville, Va.), 2024-05, Vol.26 (5), p.922-932
Ort / Verlag
England
Erscheinungsjahr
2024
Quelle
Oxford Journals 2020 Medicine
Beschreibungen/Notizen
  • The aim of this clinical trial was to compare Fluorescein-stained intraoperative confocal laser endomicroscopy (CLE) of intracranial lesions and evaluation by a neuropathologist with routine intraoperative frozen section (FS) assessment by Neuropathology. In this phase II non-inferiority, prospective, multicenter, non-randomized, off-label clinical trial (Eudra-CT: 2019-004512-58), patients above the age of 18 years with any intracranial lesion scheduled for elective resection were included. The diagnostic accuracies of both CLE and FS referenced with the final histopathological diagnosis were statistically compared in a non-inferiority analysis, representing the primary endpoint. Secondary endpoints included the safety of the technique and time expedited for CLE and FS. 210 patients were included by 3 participating sites between November 2020 and June 2022. Most common entities were high grade gliomas (37.9%), metastases (24.1%), and meningiomas (22.7%), A total of 6 serious adverse events in 4 (2%) patients were recorded. For the primary endpoint, the diagnostic accuracy for CLE was inferior with .87 versus .91 for FS, resulting in a difference of .04 (95% confidence interval -.10; .02; p=.367). The median time expedited until intraoperative diagnosis was 3 minutes for CLE and 27 minutes for FS, with a mean difference of 27.5 minutes (standard deviation 14.5; p<.001). CLE allowed for a safe and time-effective intraoperative histological diagnosis with a diagnostic accuracy of 87% across all intracranial entities included. The technique achieved histological assessments in real-time with a tenfold reduction of processing time compared to FS, which may invariably impact surgical strategy on the fly.
Sprache
Englisch
Identifikatoren
ISSN: 1522-8517
eISSN: 1523-5866
DOI: 10.1093/neuonc/noae006
Titel-ID: cdi_proquest_miscellaneous_2929057385
Format

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX