Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...

Details

Autor(en) / Beteiligte
Titel
Attenuation correction and truncation completion for breast PET/MR imaging using deep learning
Ist Teil von
  • Physics in medicine & biology, 2024-02, Vol.69 (4), p.45031
Ort / Verlag
England: IOP Publishing
Erscheinungsjahr
2024
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Simultaneous PET/MR scanners combine the high sensitivity of MR imaging with the functional imaging of PET. However, attenuation correction of breast PET/MR imaging is technically challenging. The purpose of this study is to establish a robust attenuation correction algorithm for breast PET/MR images that relies on deep learning (DL) to recreate the missing portions of the patient's anatomy (truncation completion), as well as to provide bone information for attenuation correction from only the PET data. Data acquired from 23 female subjects with invasive breast cancer scanned with 18F-fluorodeoxyglucose PET/CT and PET/MR localized to the breast region were used for this study. Three DL models, U-Net with mean absolute error loss (DL ) model, U-Net with mean squared error loss (DL ) model, and U-Net with perceptual loss (DL ) model, were trained to predict synthetic CT images (sCT) for PET attenuation correction (AC) given non-attenuation corrected (NAC) PET images as inputs. The DL and Dixon-based sCT reconstructed PET images were compared against those reconstructed from CT images by calculating the percent error of the standardized uptake value (SUV) and conducting Wilcoxon signed rank statistical tests. sCT images from the DL model, the DL model, and the DL model were similar in mean absolute error (MAE), peak-signal-to-noise ratio (PSNR), and normalized cross-correlation (NCC). No significant difference in SUV was found between the PET images reconstructed using the DL and DL sCTs compared to the reference CT for AC in all tissue regions. All DL methods performed better than the Dixon-based method according to SUV analysis. A 3D U-Net with MSE or perceptual loss model can be implemented into a reconstruction workflow, and the derived sCT images allow successful truncation completion and attenuation correction for breast PET/MR images.
Sprache
Englisch
Identifikatoren
ISSN: 0031-9155
eISSN: 1361-6560
DOI: 10.1088/1361-6560/ad2126
Titel-ID: cdi_proquest_miscellaneous_2917865548

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX