Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 24 von 51

Details

Autor(en) / Beteiligte
Titel
'Single-shot' pulmonary vein isolation using a novel lotos pulsed field ablation catheter: a pre-clinical evaluation of feasibility, safety, and 30-day efficacy
Ist Teil von
  • Europace (London, England), 2023-12, Vol.26 (1)
Ort / Verlag
England
Erscheinungsjahr
2023
Quelle
Oxford Journals 2020 Medicine
Beschreibungen/Notizen
  • Pulsed field ablation (PFA) is emerging as a non-thermal, tissue-specific technique for pulmonary vein isolation (PVI) in atrial fibrillation therapy. This pre-clinical study aims to investigate the feasibility and safety of PVI using a novel PFA system including a nanosecond-scale PFA generator, a novel lotos PFA catheter, and a customized 12 Fr steerable sheath. A total of 11 Yorkshire swine were included in this study, with 4 in the acute cohort and 7 in the chronic cohort. Under general anaesthesia, transseptal puncture and pulmonary vein (PV) angiography was initially performed. The PFA catheter was navigated to position at the right and left PV antrum after the electroanatomic reconstruction of the left atrium. Biphasic PFA applications were performed on PVs in both the spindle-shaped and the lotos-shaped poses. Pulmonary vein isolation and PFA-associated safety were assessed 30 min after ablation in both cohorts and 30 days later in the chronic cohort. Detailed necropsy and histopathology were performed. Additional intracardiac echocardiography and coronary angiogram were evaluated for safety. All target PVs (n = 20) were successfully isolated on the first attempt. No spasm of coronary artery or microbubble was seen during the procedure. Eleven of 12 PVs (91.6%) remained in isolation at the 30-day invasive study. No evidence of PV stenosis was observed in any targets. However, transient diaphragm capture occurred in 17.6%. Histopathological examinations showed no evidence of collateral injury. This study provides scientific evidence demonstrating the safety and efficacy of the novel PFA catheter and system for single-shot PVI, which shows great potential.
Sprache
Englisch
Identifikatoren
ISSN: 1099-5129
eISSN: 1532-2092
DOI: 10.1093/europace/euad362
Titel-ID: cdi_proquest_miscellaneous_2903858786

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX