Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...

Details

Autor(en) / Beteiligte
Titel
Adopting duplex sequencing technology for genetic toxicity testing: A proof-of-concept mutagenesis experiment with N-ethyl-N-nitrosourea (ENU)-exposed rats
Ist Teil von
  • Mutation research. Genetic toxicology and environmental mutagenesis, 2023-10, Vol.891, p.503669-503669, Article 503669
Ort / Verlag
Netherlands: Elsevier B.V
Erscheinungsjahr
2023
Quelle
MEDLINE
Beschreibungen/Notizen
  • Duplex sequencing (DS) is an error-corrected next-generation sequencing method in which molecular barcodes informatically link PCR-copies back to their source DNA strands, enabling computational removal of errors in consensus sequences. The resulting background of less than one artifactual mutation per 107 nucleotides allows for direct detection of somatic mutations. TwinStrand Biosciences, Inc. has developed a DS-based mutagenesis assay to sample the rat genome, which can be applied to genetic toxicity testing. To evaluate this assay for early detection of mutagenesis, a time-course study was conducted using male Hsd:Sprague Dawley SD rats (3 per group) administered a single dose of 40 mg/kg N-ethyl-N-nitrosourea (ENU) via gavage, with mutation frequency (MF) and spectrum analyzed in stomach, bone marrow, blood, and liver tissues at 3 h, 24 h, 7 d, and 28 d post-exposure. Significant increases in MF were observed in ENU-exposed rats as early as 24 h for stomach (site of contact) and bone marrow (a highly proliferative tissue) and at 7 d for liver and blood. The canonical, mutational signature of ENU was established by 7 d post-exposure in all four tissues. Interlaboratory analysis of a subset of samples from different tissues and time points demonstrated remarkable reproducibility for both MF and spectrum. These results demonstrate that MF and spectrum can be evaluated successfully by directly sequencing targeted regions of DNA obtained from various tissues⁠, a considerable advancement compared to currently used in vivo gene mutation assays. •Duplex Sequencing is an ecNGS technology that directly quantifies mutations.•ENU-dependent mutagenesis was clearly evident at 7 d in all tissues that were tested.•Multiple tissues exhibited the canonical ENU mutation spectrum 7 d after exposure.•Results obtained with Duplex Sequencing were highly concordant between laboratories.•The DuplexSeq™ Mutagenesis Assay is promising for genetic toxicity testing.
Sprache
Englisch
Identifikatoren
ISSN: 1383-5718, 1879-3592
eISSN: 1879-3592
DOI: 10.1016/j.mrgentox.2023.503669
Titel-ID: cdi_proquest_miscellaneous_2870987414

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX