Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 10 von 233

Details

Autor(en) / Beteiligte
Titel
Cross-cultural translation into Chinese and psychometric evaluation of a screening tool for nocturia: the Targeting the individual's Aetiology of Nocturia to Guide Outcomes (TANGO) questionnaire
Ist Teil von
  • Hong Kong Medical Journal, 2023-08, Vol.29 (4), p.311-321
Ort / Verlag
China: Hong Kong Academy of Medicine
Erscheinungsjahr
2023
Quelle
Free E-Journal (出版社公開部分のみ)
Beschreibungen/Notizen
  • We conducted translation and psychometric validation of a self-administered, 22-item dichotomous response-based questionnaire to identify nocturia aetiologies and co-morbidities in adult patients. The Targeting the individual's Aetiology of Nocturia to Guide Outcomes (TANGO) questionnaire was forward- and backward-translated, then finalised using a standardised methodology. The resulting version, a Chinese version of the TANGO [TANGO (CV)], was evaluated for internal consistency, test-retest reliability, content validity, convergent validity, criterion validity, and discriminant validity via responses from 65 participants (46 men and 19 women; mean age, 67 years, range, 50-88), in comparison with other validated questionnaires and a 4-day bladder/sleep diary. Only 0.4% of responses were missing; 3% of participants required assistance with comprehension. The Kuder-Richardson Formula 20 (KR-20) coefficient for the whole tool was 0.711. Kappa values for individual domains and the whole tool varied from 0.871 to 0.866, indicating satisfactory test-retest reliability. There was strong agreement between the sum of positive responses to each domain and the whole tool (intra-class correlation coefficient=0.878-1.000). Modest correlations (ρ=0.4-0.6) were detected between the tool and bladder/sleep diary-based parameters for convergent validity. Criterion validity was confirmed for each domain and the whole tool [ρ=0.287-0.687]. In receiver operating characteristic analysis, the tool could distinguish patients (≥2 nocturia episodes/night) from controls (≤1 nocturia episode/night) [Youden's J statistic=0.453, area under the curve=0.818, 95% confidence interval (CI)=0.683-0.953] and patients with significant nocturia distress from patients with mild nocturia distress (Youden's J statistic=0.398, area under the curve=0.729, 95% CI=0.581-0.878). The TANGO (CV) was formally crossculturally adapted and translated. Its psychometric properties (except sensitivity to change) were validated.
Sprache
Englisch; Chinesisch
Identifikatoren
ISSN: 1024-2708
eISSN: 2226-8707
DOI: 10.12809/hkmj219261
Titel-ID: cdi_proquest_miscellaneous_2845656390

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX