Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 3 von 17

Details

Autor(en) / Beteiligte
Titel
Clinical Utility of Plantar Pressure Measurements as Screening in Patients With Parkinson Disease With and Without Freezing of Gait History
Ist Teil von
  • Archives of physical medicine and rehabilitation, 2023-07, Vol.104 (7), p.1091-1098
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2023
Quelle
MEDLINE
Beschreibungen/Notizen
  • •Parkinson disease represented higher pressure-time integral (PTI) on total foot areas during dynamic conditions.•Peak pressure, contact area, and PTI on hallux during static conditions were significantly lower in freezing of gait.•Based on our study, PTI may be valuable in auxiliary diagnosis. To test the feasibility of objective assessments using the TekScan MatScan pressure mat plantar pressure measurement as a time-effective screening service for Parkinson disease (PD) with and without freezing of gait (FOG) history. Prospective cross-sectional study. Largest medical center in southern Taiwan. Not applicable. Plantar pressure measurements including average peak pressure (PP), contact area (CA), and pressure-time integral (PTI) in static and dynamic conditions as well as clinical scores during off-medication states. A total of 103 patients with PD and 22 age- and sex-matched volunteers without PD (N=125). Plantar pressure assessment including PP, CA, and PTI on the total foot areas between participants with PD and controls without PD in the static conditions are similar. Patients with PD presented higher PTI on total foot areas as well as hallux, midfoot area, and medial and lateral heels during dynamic conditions than controls without PD. The PP, CA, and PTI during the static condition and CA during the dynamic condition on the hallux showed statistical significance between PD with and without FOG history. Stepwise logistic regression after controlling with age and body mass index showed only PTI on hallux (static conditions) was significantly associated with the presence of FOG. The receiver operating characteristic curve analysis in diagnostic accuracy for FOG in PTI was statistically significant (P=.002; area under the curve, 0.71). FOG screening using the TekScan MatScan pressure mat plantar pressure measurement could serve as a time-effective screening service at the outpatient clinic. Based on our study, PTI may be valuable in auxiliary diagnosis.
Sprache
Englisch
Identifikatoren
ISSN: 0003-9993
eISSN: 1532-821X
DOI: 10.1016/j.apmr.2023.02.019
Titel-ID: cdi_proquest_miscellaneous_2790051523

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX