Modeling of electrostatic spray in a venturi scrubber
Journal of chemical technology and biotechnology (1986), 2003-02, Vol.78 (2-3), p.181-186
Yang, H T
Viswanathan, S
Balachandran, W
Ray, M B
2003
Volltextzugriff (PDF)
Details
Autor(en) / Beteiligte
Yang, H T
Viswanathan, S
Balachandran, W
Ray, M B
Titel
Modeling of electrostatic spray in a venturi scrubber
Ist Teil von
Journal of chemical technology and biotechnology (1986), 2003-02, Vol.78 (2-3), p.181-186
Ort / Verlag
Chichester, UK: John Wiley & Sons, Ltd
Erscheinungsjahr
2003
Quelle
Wiley-Blackwell Journals
Beschreibungen/Notizen
This paper summarizes the results of an investigation into the distribution of the droplets produced by electrostatic nozzles inside a Pease–Anthony venturi scrubber. The model simulates the flux distribution of charged droplets injected from an electrostatic nozzle in the scrubber under the combined influence of hydrodynamic and electric fields. The effects of operating parameters, such as gas velocity, diameter of the scrubbing droplets, charge‐to‐mass ratio and liquid‐to‐gas ratio, on the flux distribution of the water droplets in the throat of the scrubber are also investigated. The model takes into account initial liquid momentum, electric, hydrodynamic and gravitational forces, and eddy diffusion. The flux distribution of the scrubbing liquid in the presence of an electric field is much improved over a conventional scrubber, and the effect increases with the increase in charge‐to‐mass ratio. However, the effect of an electric field on the droplet flow pattern for small drops in a strong hydrodynamic field is negligible. Simulated results are in good agreement with the experimental data obtained in the laboratory. © 2003 Society of Chemical Industry
Sprache
Englisch
Identifikatoren
ISSN: 0268-2575
eISSN: 1097-4660
DOI: 10.1002/jctb.730
Titel-ID: cdi_proquest_miscellaneous_27849824
Format
–
Schlagworte
Applied sciences
,
Atmospheric pollution
,
charge-to-mass ratio
,
droplet diameter
,
electric force
,
Exact sciences and technology
,
flux distribution
,
General processes of purification and dust removal
,
Pollution
,
Prevention and purification methods
,
venturi scrubber