Validation of a blood gas device for ionized calcium analysis in Holstein cows
Ist Teil von
  • Veterinary clinical pathology, 2023-06, Vol.52 (2), p.276-283
Ort / Verlag
United States: Wiley Subscription Services, Inc
Erscheinungsjahr
2023
Link zum Volltext
Quelle
Wiley-Blackwell Journals
Beschreibungen/Notizen
  • Background Accurate analysis of ionized calcium (iCa) is critical for the detection of hypocalcemia or subclinical hypocalcemia. The Edan i15 Vet (EDAN) blood gas device has not been validated for iCa in dairy cows. Objectives We aimed to validate the EDAN blood gas device against the Gem Premier 3000 (GEM) analyzer by measuring iCa concentrations and evaluating the ability of these measurements, compared with serum total calcium (TCa) concentrations, to diagnose subclinical hypocalcemia. Methods iCa concentrations were measured with the EDAN and GEM devices, and serum TCa concentrations were measured with a wet biochemistry method with blood from 125 lactating Holstein cows between calving to day 27 postpartum. Results Bland‐Altman plots showed a mean and total bias of 0.05 and 0.24 mmol/L for the EDAN device, respectively. The intercept did not include zero, but the slope included 1.0 in the Passing‐Bablok regression. The sensitivity and specificity (Se/Sp) of the EDAN device were 93/94%, 93/90%, 91/93%, and 85/95% for iCa cut‐off values of <1.00, 1.05, 1.10, and 1.15 mmol/L, respectively, as determined with the GEM device. The Se/Sp were 57/82% and 72/80% for EDAN and 57/80% and 72/79% for GEM at serum TCa cut‐off points <2.15 and <2.00 mmol/L, respectively. The average iCa concentrations analyzed with the GEM and EDAN devices were 1.04 ± 0.18 and 1.09 ± 0.17, respectively. Conclusions The EDAN device did not have satisfactory agreement with GEM and could not be used interchangeably, but it had satisfactory Se/Sp to diagnose subclinical hypocalcemia compared with the GEM‐derived iCa cut‐off points. Serum TCa concentration cut‐off values were not suitable for diagnosing subclinical hypocalcemia because of unsatisfactory Se/Sp compared with iCa concentrations analyzed by the GEM and EDAN devices. The iCa values analyzed using the EDAN and GEM devices were consistent with previously reported data.
Sprache
Englisch
Identifikatoren
ISSN: 0275-6382
eISSN: 1939-165X
DOI: 10.1111/vcp.13233
Titel-ID: cdi_proquest_miscellaneous_2780762367
Format
Schlagworte
calcium, cattle, Edan, gem, Hypocalcemia

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX