Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 16 von 263

Details

Autor(en) / Beteiligte
Titel
Development of a digital anti-Müllerian hormone immunoassay: ultrasensitive, accurate and practical strategy for reduced ovarian reserve monitoring and assessment
Ist Teil von
  • Talanta (Oxford), 2023-02, Vol.253, p.123970-123970, Article 123970
Ort / Verlag
Netherlands: Elsevier B.V
Erscheinungsjahr
2023
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Anti-Müllerian hormone (AMH) is an ideal biomarker for the assessment of ovarian reserve. However, its application in determining ovarian reserve reduction is restricted due to the low sensitivity of existing AMH assays. Herein, a homebrew ultrasensitive digital AMH assay (UD-AMH) was established based on a single-molecule array (SiMoA, HD-X platform), and the analytical performance of UD-AMH was evaluated systematically. The limit of detection (LoD) and limit of quantitation (LoQ) of UD-AMH were 0.13 and 0.14 pg/mL, respectively, which is approximately 100-fold higher than that of the current reported general clinical AMH assay. A comparison study showed a high correlation, with r = 0.988 for the Beckman Access AMH assay and r = 0.945 for the Kangrun AMH assay. In addition, we found that the AMH concentrations of premature ovarian insufficiency (POI) patients were very low (2.59 (0.86, 31.79) pg/mL) and similar to those of perimenopausal women (2.37 (0.65, 35.88) pg/mL) but significantly higher than those of menopausal women (0.43 (0.28, 1.17) pg/mL). Furthermore, we observed that the AMH concentration of most hormone therapy (HT) treated POI patients decreased sharply, suggesting that the ovarian reserve of POI patients declines over time even under HT-treatment. [Display omitted] •Developing a digital AMH immunoassay (UD-AMH) based on the single-molecule array technology.•The sensitivity of this assay is 100-fold higher than that of conventional clinical AMH assay.•This assay could accurately detect almost all samples that undetected by conventional AMH assay.•The UD-AMH assay successfully realized the evaluation of decreased ovarian reserve of ovarian insufficiency women.
Sprache
Englisch
Identifikatoren
ISSN: 0039-9140
eISSN: 1873-3573
DOI: 10.1016/j.talanta.2022.123970
Titel-ID: cdi_proquest_miscellaneous_2723161918

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX