Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 20 von 1067

Details

Autor(en) / Beteiligte
Titel
Low-energy (360 J) radiofrequency catheter ablation using moderate power − short duration: proof of concept based on in silico modeling
Ist Teil von
  • Journal of interventional cardiac electrophysiology, 2023-08, Vol.66 (5), p.1085-1093
Ort / Verlag
New York: Springer US
Erscheinungsjahr
2023
Quelle
SpringerNature Journals
Beschreibungen/Notizen
  • Background Pilot clinical studies suggest that very high power–very short duration (vHPvSD, 90 W/4 s, 360 J energy) is a feasible and safe technique for ablation of atrial fibrillation (AF), compared with standard applications using moderate power–moderate duration (30 W/30 s, 900 J energy). However, it is unclear whether alternate power and duration settings for the delivery of the same total energy would result in similar lesion formation. This study compares temperature dynamics and lesion size at different power-duration settings for the delivery of equivalent total energy (360 J). Methods An in silico model of radiofrequency (RF) ablation was created using the Arrhenius function to estimate lesion size under different power-duration settings with energy balanced at 360 J: 30 W/12 s (MPSD), 50 W/7.2 s (HPSD), and 90 W/4 s (vHPvSD). Three catheter orientations were considered: parallel, 45°, and perpendicular. Results In homogenous tissue, vHPvSD and HPSD produced similar size lesions independent of catheter orientation, both of which were slightly larger than MPSD (lesion size 0.1 mm deeper, ~ 0.7 mm wider, and ~ 25 mm 3 larger volume). When considering heterogeneous tissue, these differences were smaller. Tissue reached higher absolute temperature with vHPvSD and HPSD (5–8 °C higher), which might increase risk of collateral tissue injury or steam pops. Conclusion Ablation for AF using MPSD or HPSD may be a feasible alternative to vHPvSD ablation given similar size lesions with similar total energy delivery (360 J). Lower absolute tissue temperature and slower heating may reduce risk of collateral tissue injury and steam pops associated with vHPvSD and longer applications using moderate power.
Sprache
Englisch
Identifikatoren
ISSN: 1572-8595, 1383-875X
eISSN: 1572-8595
DOI: 10.1007/s10840-022-01292-z
Titel-ID: cdi_proquest_miscellaneous_2686055341

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX