Monte Carlo optimization and experimental validation of a prototype ionization chamber for accurate magnetic resonance image guided radiation therapy (MRgRT) daily output constancy measurements in solid phantoms
Ist Teil von
  • Medical physics (Lancaster), 2022-08, Vol.49 (8), p.5483-5490
Ort / Verlag
United States
Erscheinungsjahr
2022
Quelle
Wiley Online Library
Beschreibungen/Notizen
  • Purpose To optimize the design, develop and test a prototype ionization chamber for accurate daily output constancy measurements in solid phantoms in clinical magnetic resonance‐guided radiation therapy (MRgRT) radiotherapy beams. Up to 4% variations in response using commercial ionization chambers have been previously reported; the prototype ionization chamber developed here aims to minimize these variations. Methods Monte Carlo simulations with the EGSnrc code system are used to optimize an ionization chamber design by increasing the thickness of a brass (high‐density, nonferromagnetic, easy‐to‐machine) wall until results consistent with no air gap are produced for simulations with a 1.5 T and 0.35 T magnetic field, with a 0.2 mm air gap and varying the placement of the chamber model within the air gap. Based on the results of these simulations, prototype ionization chambers are manufactured and tested in conventional linac beams and in a 7 MV Elekta Unity MR‐linac. The chambers are rotated about their axes, both parallel and perpendicular to the 1.5 T magnetic field, through 360º in a plastic phantom with measurements made at each cardinal angle. This reveals any variation in chamber response by varying the thickness of the air gap between the chamber and the phantom. Results Monte Carlo simulations demonstrate that the optimal thickness of the chamber wall to mitigate the effect of an asymmetric air gap between the chamber and the plastic phantom is 1.1 mm of brass. With this thickness, the differences between simulations with and without an air gap and with asymmetric placement of the chamber within the air gap are less than 0.2%. A prototype chamber constructed with a 1.1 mm brass wall thickness exhibits less than 0.3% variation in response when rotated about its axis in the plastic phantom in a beam from an MR‐linac, independent of whether its axis is parallel or perpendicular to the magnetic field. Conclusion The optimized ionization chamber design and validated prototype for accurate MR‐linac daily output constancy measurements allows utilization of conventional phantoms and procedures in MRgRT systems. This can minimize disruption to clinical workflow for MR‐linac quality assurance measurements.
Sprache
Englisch
Identifikatoren
ISSN: 0094-2405
eISSN: 2473-4209
DOI: 10.1002/mp.15695
Titel-ID: cdi_proquest_miscellaneous_2661955112

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX