Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 26 von 67

Details

Autor(en) / Beteiligte
Titel
Relation Between Pulmonary Artery Pressures Measured Intraoperatively and at One-Year Catheterization After Unifocalization and Repair of Tetralogy With Major Aortopulmonary Collateral Arteries
Ist Teil von
  • Seminars in thoracic and cardiovascular surgery, 2022-01, Vol.34 (3), p.1013-1025
Ort / Verlag
United States: Elsevier Inc
Erscheinungsjahr
2022
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • To assess the relationships between pulmonary artery (PA) pressure and the PA: aortic systolic pressure ratio measured intraoperatively and at surveillance catheterization in patients achieving complete unifocalization and repair for tetralogy of Fallot with major aortopulmonary collateral arteries (TOF/MAPCAs). This was a single-center retrospective cohort analysis of all patients who underwent complete repair of TOF/MAPCAs from 2002 to 2019 and received a postoperative surveillance catheterization at our center 6-24 months after surgery. Associations between intraoperative and catheter hemodynamic data were analyzed. A total of 163 patients were included. Median systolic PA pressure was 30 (quartiles 26, 35) and 35 (28, 42) mm Hg intraoperatively and at catheterization respectively; systolic aortic pressure 90 (86, 100) and 84 (76, 92); and PA:aortic pressure ratio was 0.33 (0.28, 0.40) and 0.41 (0.34, 0.49). Moderate correlation was found between the intraoperative and catheter-based hemodynamics, with the majority of systolic PA pressures within 10 mm Hg and PA:Ao systolic ratios within 0.1. Changes in the ratio were influenced to a similar degree by differences in PA and aortic pressures. Surgical and/or catheter reinterventions were more common in patients with both higher intraoperative PA systolic pressure and PA:aortic systolic ratios and in those with a greater discrepancy between intraoperative and catheterization values. PA systolic pressure and the PA:aortic systolic pressure ratio measured immediately after repair remains useful metrics for assessing the initial operative PA reconstruction, and as indicators of longer-term hemodynamics. Initially elevated and subsequently discrepant PA systolic pressure and PA:aortic systolic pressure ratios were associated with higher rates of reintervention. [Display omitted]
Sprache
Englisch
Identifikatoren
ISSN: 1043-0679
eISSN: 1532-9488
DOI: 10.1053/j.semtcvs.2022.01.004
Titel-ID: cdi_proquest_miscellaneous_2623880134

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX