Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 11 von 49

Details

Autor(en) / Beteiligte
Titel
Leadless pacemaker implantation after lead extraction for cardiac implanted electronic device infection
Ist Teil von
  • Journal of cardiovascular electrophysiology, 2022-03, Vol.33 (3), p.464-470
Ort / Verlag
United States: Wiley Subscription Services, Inc
Erscheinungsjahr
2022
Quelle
MEDLINE
Beschreibungen/Notizen
  • Background Cardiac implanted electronic device (CIED) pocket and systemic infection remain common complications with traditional CIEDs and are associated with high morbidity and mortality. Leadless pacemakers may be an attractive pacing alternative for many patients following complete hardware removal for a CIED infection by eliminating surgical pocket‐related complications as well as lower risk of recurrent complications. Objective To describe use and outcomes associated with leadless pacemaker implantation following extraction of a CIED system due to infection. Methods Patient characteristics and postprocedural outcomes were described in patients who underwent leadless pacemaker implantation at Duke University Hospital between November 11, 2014 and November 18, 2019, following CIED infection and device extraction. Outcomes of interest included procedural complications, pacemaker syndrome, need for system revision, and recurrent infection. Results Among 39 patients, the mean age was 71 ± 17 years, 31% were women, and the most frequent primary pacing indication was complete heart block (64.1%) with 9 (23.1%) patients being pacemaker dependent at the time of Micra implantation. The primary organism implicated in the CIED infection was Staphylococcus aureus (43.6%). Nine of the 39 patients had a leadless pacemaker implanted before or on the same day as their extraction procedure, and the remaining 30 patients had a leadless pacemaker implanted after their extraction procedure. During follow‐up (mean 24.8 ± 14.7 months) after leadless pacemaker implantation, there were a total of 3 major complications: 1 groin hematoma, 1 femoral arteriovenous fistula, and 1 case of pacemaker syndrome. No patients had evidence of recurrent CIED infection after leadless pacemaker implantation. Conclusions Despite a prior CIED infection and an elevated risk of recurrent infection, there was no evidence of CIED infection with a mean follow up of over 2 years following leadless pacemaker implantation at or after CIED system removal. Larger studies with longer follow‐up are required to determine if there is a long‐term advantage to implanting a leadless pacemaker versus a traditional pacemaker following temporary pacing when needed during the periextraction period in patients with a prior CIED infection.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX