Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 19 von 83

Details

Autor(en) / Beteiligte
Titel
Development of a microneutralization assay for HSV-2
Ist Teil von
  • Journal of virological methods, 2021-11, Vol.297, p.114268-114268, Article 114268
Ort / Verlag
Netherlands: Elsevier B.V
Erscheinungsjahr
2021
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • •An HSV-2 MNA assay correlates with PRNT with and without the addition of complement.•MNA shows greater through-put and 90% reduction in assay time compared to the PRNT.•Human anti-HSV mAbs for virus detection show specificity for HSV gC and gE.•Binding of HSV-1 infected cells to the Fc portion of non-immune human IgG is shown. Plaque Reduction Neutralization Test (PRNT) is the standard assay used for measuring neutralizing antibody responses to Herpes simplex virus type-2 (HSV-2). The PRNT is a cumbersome, time-consuming and laborious assay. The development of a faster, high throughput microneutralization assay (MNA) for HSV-2 viruses carried out in a 96-well format will allow for rapid testing of large numbers of samples for drug and vaccine development. We describe the generation of a MNA that utilizes a pair of anti-HSV human monoclonal antibodies (mAbs) for virus detection in HSV-2 infected Vero cells. Antibodies were generated by B-cell cloning from PBMC’s isolated from HSV-1 negative/HSV-2 positive donors. We describe the selection and characterization of the antibodies used for virus detection by ELISA with purified, recombinant anti-HSV glycoproteins, antibody binding in infected cells, and Western Blot. We determine the anti-HSV-2 neutralizing titers of immune sera from mice by MNA and PRNT and compare these results by linear regression analysis. We show that neutralization titers for HSV-2, determined by the 96-well MNA correlate with titers determined by a PRNT completed in 24-well plates in both the absence (R2 = 0.8250) and presence (R2 = 0.7075) of complement. We have successfully developed an MNA that can be used in place of the burdensome PRNT to determine anti-HSV-2 neutralizing activity in serum. This MNA has much greater throughput than the PRNT, allowing many more samples to be processed in a shorter time saving ∼90 % of the time required by the laboratory scientist to complete the task as compared to the traditional PRNT.
Sprache
Englisch
Identifikatoren
ISSN: 0166-0934
eISSN: 1879-0984
DOI: 10.1016/j.jviromet.2021.114268
Titel-ID: cdi_proquest_miscellaneous_2566045995

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX