Comparison of bone remodelling around short stem and conventional straight stem in total hip replacement: a prospective randomized radiographic and dual-energy X-ray absorptiometric study
Ist Teil von
  • Bratislavské lékarské listy, 2021-01, Vol.122 (8), p.548-554
Erscheinungsjahr
2021
Link zum Volltext
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • OBJECTIVEThe aim of study was to evaluate periprosthetic bone mineral density (BMD) changes of proximal femur, osseointegration and clinical outcomes after implantation of short-stemmed and conventional straight-stemmed prostheses. METHODSThis prospective, randomized study included 50 patients with unilateral total hip replacement. The patients were randomized into 2 cohorts: patients with a cementless short stem Metha (n=25) and patients with a cementless conventional straight stem Bicontact evaluated as the control (n=25). Periprosthetic BMD changes were measured using a DEXA performed at one-week, 3-monts, 6-months and 1-year follow up. Clinical evaluation with Harris hip score (HHS) and radiographic assessment were performed through a 1 year follow up. RESULTSCompared to 1-week postoperative assessment, there were differences in BMD changes between the groups at the final follow-up in all ROIs, with statistical significances in ROI 1, 2, 3, 6 and 7. The loss of periprosthetic BMD in all ROIs around straight stems at each time-point was observed. There was a tendency towards a regain of BMD in all ROIs at 1-year follow-up compared to the 3-months postoperative assessment with the short stems. Less pronounced bone loss was observed around the short stems that the straight stems in ROI 1 (‒2.9 % % vs ‒16.2 %), 5 (‒4.7 % vs ‒8.9 %) and 7 (‒8.6 % vs ‒20 %). The periprosthetic BMD exceeded baseline values in the short stem cohort in ROI 2 (+4.4 % vs ‒5 %), 3 (+5.6 % vs ‒2.5 %) and 6 (+4.3 % vs ‒10 %). All stems had a radiographically stable fixation. Stress shielding-related bone resorption was markedly lower in the short stem cohort. The HHS score was comparable between the two cohorts. CONCLUSIONThe implant-specific stress shielding altered the proximal loading condition for both stems; however, the results of this study suggest a more physiological strain distribution with the short stems versus the straight stems (Tab. 3, Fig. 3, Ref. 25).
Sprache
Englisch
Identifikatoren
ISSN: 0006-9248
DOI: 10.4149/BLL_2021_087
Titel-ID: cdi_proquest_miscellaneous_2553522380
Format

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX