Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 21 von 1433
Journal of the mechanical behavior of biomedical materials, 2021-09, Vol.121, p.104646-104646, Article 104646
2021
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Effect of thermocycling on the surface properties of CAD-CAM denture base materials after different surface treatments
Ist Teil von
  • Journal of the mechanical behavior of biomedical materials, 2021-09, Vol.121, p.104646-104646, Article 104646
Ort / Verlag
Elsevier Ltd
Erscheinungsjahr
2021
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • To evaluate the effect of thermocycling on the water contact angle (WCA), surface roughness (SR), and microhardness (MH) of different CAD-CAM PMMA denture base materials after different surface treatments (conventional laboratory polishing, polishing kit, or surface sealant). Disk-shaped specimens (10 × 2 mm) of 3 different CAD-CAM PMMAs, AvaDent (AV); Merz M-PM (M-PM); Polident (Poli), and a conventional heat-polymerized PMMA (Vynacron) (CV) (n=21) were divided into 3 different surface treatment groups (n=7): conventional laboratory polishing (CLP), polishing with acrylic resin polisher kit (PK), and a surface sealant (Palaseal) (SSC). Stereomicroscopic images were taken both before and after thermocycling. WCA, SR, and MH of all specimens were measured before and after thermocycling and compared by using a 2-way ANOVA (α=0.05). After thermocycling, WCA significantly increased for CLP- or PK -applied (P<.001) specimens of all materials and SSC-applied M-PM (P=.002), SR significantly increased for CLP-applied M-PM (P=.027) and PK-applied Poli (P=.041), and MH significantly decreased for CLP- or PK-applied AV (P = .001, P < .001, respectively), CV (P=.033, P=.023, respectively), and M-PM (P=.003, P=.001, respectively), SSC-applied M-PM (P<.001), and CLP-applied Poli (P<.001). Stereomicroscopic images revealed rougher surfaces for PK-applied specimens. After thermocycling, surface treatment had a significant effect on water contact angle and surface roughness. CLP or PK application resulted in hydrophobic surfaces compared with before thermocycling. CLP or SSC application on CAD-CAM PMMAs resulted in smoother surfaces. Thermocycling lowered the microhardness of all PMMAs, and the decrease was significant in CLP- or PK-applied PMMAs, except for PK-applied Poli. [Display omitted] •The interaction of material and surface treatment affects the physical and mechanical properties of different PMMA materials.•Thermocycling affects the surface properties of CAD-CAM and heat-cured PMMA denture base materials.•Polishing kit results in rougher surfaces on tested PMMAs.
Sprache
Englisch
Identifikatoren
ISSN: 1751-6161
eISSN: 1878-0180
DOI: 10.1016/j.jmbbm.2021.104646
Titel-ID: cdi_proquest_miscellaneous_2545604130

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX