Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 10 von 516
Archives of orthopaedic and trauma surgery, 2021-08, Vol.141 (8), p.1401-1409
2021

Details

Autor(en) / Beteiligte
Titel
Can a simple iPad app improve C-arm based component position in anterior THA?
Ist Teil von
  • Archives of orthopaedic and trauma surgery, 2021-08, Vol.141 (8), p.1401-1409
Ort / Verlag
Berlin/Heidelberg: Springer Berlin Heidelberg
Erscheinungsjahr
2021
Link zum Volltext
Quelle
SpringerLink (Online service)
Beschreibungen/Notizen
  • Introduction Correct acetabular component positioning improves hip biomechanics, impingement free range of motion and may lead to a reduced risk of postoperative dislocation. The C-arm is a simple and cost-effective tool for THA in a supine position, however, evaluation of the images can be challenging due to parallax. The current study aimed to investigate whether a software app-based measurement technique can control acetabular component position and leg length in anterior THA. Materials and methods Ninety-three patients with end-stage osteoarthritis aged 65.2 ± 9.6 years (range 30–86 years) were included in this prospective study. All patients underwent direct anterior THA using a Hana orthopedic surgery table. C-arm imaging and an iPad software app were used to determine intraoperative acetabular anteversion, inclination and leg length discrepancy. The app provides a measuring tool that is applied to intraoperative c-arm images. The intraoperative measurements were compared to the measurements of standard postoperative AP-pelvis radiographs. Results Intraoperative software app-based anteversion measurements averaged 20.5° (range 16.0° to 24.0°) compared to 20.9° (range 14.7° to 25.6°) postoperatively. Mean intraoperative inclination was 40.5° (range 35° to 48°) compared to postoperative 40.7° (range 35° to 49°). Mean intraoperative leg length discrepancy was 0.9 mm (range – 4–5 mm) compared to postoperative 0.6 mm (range – 5–6 mm). A strong Pearson’s correlation was observed between the intraoperative and postoperative measurements for anteversion ( r  = .701; P  < .0001), inclination ( r  = .816; P  < .0001) and leg length discrepancy ( r  = .542; P  < .0001). Conclusions The software app used in the current study allowed for a simple and accurate measurement of intraoperative cup position and leg length in direct anterior THA.
Sprache
Englisch
Identifikatoren
ISSN: 0936-8051
eISSN: 1434-3916
DOI: 10.1007/s00402-021-03807-1
Titel-ID: cdi_proquest_miscellaneous_2489597268

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX